System Power-On; Ac Power; After Installation - Dell EMC PowerSwitch S4810-ON Installation Manual

Table of Contents

Advertisement

System power-on

Supply power to the S4810–ON after it is mounted in a rack or cabinet.
Dell Technologies recommends reinspecting your system before powering up. Verify that:
The equipment is properly secured to the rack and properly grounded.
The equipment rack is properly mounted and grounded.
The ambient temperature around the unit (which may be higher than the room temperature) is within the limits that are specified for
the S4810–ON.
There is sufficient airflow around the unit.
The input circuits are correctly sized for the loads and that you use sufficient overcurrent protection devices.
All protective covers are in place.
Blank panels are installed if you do not install optional modules.
NOTE:
A US AC power cable is included for powering up an AC power supply. You must order all other power cables
separately.
NOTE:
ESD damage can occur if components are mishandled. Always wear an ESD-preventive wrist or heel ground strap
when handling the S4810–ON system and its components.

AC Power

To add AC power, connect the power cord plug to each AC power connector. Make sure that the power cord is secure (as shown in the
following illustration).
CAUTION:
Ensure that you correctly install the PSU. When correctly installed, the AC power connector is on the left
side of the PSU and the status LED is at the top of the PSU (as shown in the following illustration).
As soon as the cable is connected between the S4810–ON and the power source, the system is powered-up; there is no on/off switch.
Figure 9. AC Power Connection
1. Power Connection
2. LED

After installation

After you have installed and powered on the S4810-ON, see your open network installation environment (ONIE)-compatible third-party
operating system documentation at
http://onie.org
to configure your system.