FLAME DIAGNOSTICS
The Flame Diagnostics screen shows a real-
time evaluation of the Pilot status, including
flame strength, DC High voltage as well as AC
voltage in millivolts.
Along with the real-time flame status, this
screen also provides Flame Fails and Relights.
On the right side of the screen displays a
graphical representation of the flame health
ranging from Strong to None. In order for the
system to register an adequate flame, the
flame must be at Weak or higher.
POWER
The Power Diagnostics displays the Voltage, Current,
System Power, as well as the Hourly Energy Consumption
of the system in real-time.
DOC-001041 / v1.0
30