RJ-45 I/O Cable Connections to cage Rear Panel
RJ-45 I/O cables for the network connection are routed from the rear panel of the
Coral IPx cage, for the following cards:
2DT (Interface #0 only)
UDT
PRI-23 and PRI-30 cards (layout UDT "C" and later)
T1 card (layout UDT "C" and later)
30T/x, 30T/E card (layout UDT "C" and later)
PUGW
UGW-E
UGW card (layout B1)
Verify that the RJ-45 cables for the above cards are not connected directly from the
network to the connectors on the front panel of Coral peripheral cards.
Only 2DT(Interface #1), IPG, DPC and old versions of UGW, T1, 30T, PRI-23
and PRI-30 cards are routed from the connectors of the front panel of Coral
peripheral cards. See
1.
Determine the route of the RJ-45 cable from the network connection to the cage
rear panel. Measure the longest distance from the cage rear panel to the
corresponding network connector.
2.
Fabricate a cable of the length determined in
connector on each end. For information on the pinout connection, see
I/O RJ-45 Connections Via Rear
3.
Connect one side of the RJ-45 cable routed in
4.
Carefully route the other side of the RJ-45 cable routed in
of the Coral IPx cage. Connect the RJ-45 connector to the corresponding RJ-45 jack.
5.
Repeat
to
step 1
step 4
page 5-25, I/O Connections Via Front
step 1
Panel.
step 1
for each peripheral card with an RJ-45 connector.
Hardware Installation Procedure
Panel.
with a male, 4 pair RJ-45
page 5-43,
to the network connection.
to the rear panel
step 1
2-29