Table 3-1
Card Slot
Status Messages
3-22
Coral IPx 800 Installation Manual
9.
Verify that the STATUS field indicates ACTIVE for each of the cards installed.
If another message is displayed, see
status messages, see Chapter 6 of the Program Interface & Database Reference Manual.
.
Displayed
Description
Message
Initialization was successfully
ACTIVE
completed.
Card is partially active because there
ACTIVE/P
are not enough resources to support
the other sub circuits on an
8DRCM-2/8DRCF card or not all tone
generators are being used on the iDSP
card.
P_TYPE and I_TYPE are not
REPLACED
compatible.
Both i_type and p_type fields should
show the required card name.
The card slot has previously been
initialized by a different card type (see
the entry for I_TYPE field, as well).
Card has not received database, or
WAIT_DB
has not reported initialization.
Insufficient system memory to initialize
NO_RESOURCES
card.
HDLC problem
FAULT
The SAU ports are limited and
UNAUTHORIZED
therefore the card is not authorized for
use in this system.
3-1. For a complete list of card slot
Table
Technical
Recommendations
None
Readjust SIZES to
support unsupported
sub circuits for
8DRCM-2/8DRCF card.
Partial Active for the
iDSP card is not
critical. Readjust the
parameter value only
when needed.
Install proper card or
enter NO_CARD in
the I_TYPE option.
Continue waiting
Check SIZES
Check HDLC wiring
Install an updated
version of the SAU
with the appropriate
amount of ports
added. Ask your
dealer for an
authorized upgrade.