Circuit Description
displays a block diagram of the PS19 AC power supply.
Figure 7-12
The PS19 AC includes one AC-DC converter and one switch-mode DC-DC converter
that convert 98-126VAC and 198-253VAC (47-63Hz) input power to:
DC outputs
Message and Ring outputs
DC Output Power
-48VDC
+5VDC
–5VDC
+12VDC
–12VDC
Message and Ring Circuits
The -120VDC and
message waiting lamps of single line telephones connected to SLT ports of the system.
–120VDC for SLT message waiting lamps
RMS for SLT ringers
85V
Ring Generator
The ring generator is capable of generating ringing up to 20 ports simultaneously at
20Hz or at 25Hz. The ringing frequency is configured by setting jumper J2 on the
PS19 AC circuit board. See
The current is used for ringing on industry standard, SLT, and magneto telephone
station ports. The ring generator provides high voltage (85V
current required by SLT station ports of the 8SLS, 16SLS, 24SLS, or 8SM cards.
Messaging
The messaging generator is capable of generating –120VDC for message lamps. It is
used to light neon lamps on SLT ports of the 8SLS, 16SLS, or 24SLS cards.
NOTE: For 8SA and 24SA cards the message and ringer generators are provided by the
8/24SA card.
RMS voltages are provided for ringers to drive the ringers and
85V
page 7-45, Ringer Frequency
Adjustment.
) ring generator
RMS
Power Supplies
7-43