Tadiran Telecom Coral IPx 800 Series Installation Procedure And Hardware Reference Manual page 138

Table of Contents

Advertisement

Table 5-2
Telephone
Circuit Primary
Lightning / Surge
Arrestor Device
Specifications
5-12
Coral IPx 800 Installation Manual
Generally, leased or switched circuit facilities provided by the local telephone utility
company are equipped with primary protection devices installed with the circuit.
However, privately owned aerial or buried cable feeding from one building to another
may not be equipped with protection devices. Always consult with whomever
provided the circuits to determine whether protection devices are present, and if so,
what type. Never assume that protection devices have been provided by another party,
or that existing protection devices are adequate.
The secondary protection has to include a leakage current protector in series of every
wire, tip and ring, on every port that is either connected to the public telephone
network or to an out of the building cable. The requirement is in accordance with UL
Specification 60950, Third Edition or CSA C22.2 No. 60950. The required protectors can
be mounted directly on a 66 block in the MDF.
Specification
Construction
Primary Element
Fail-safe Metallic Shunt
Vent Safe Spark Gap
Heat Coil (recommended)
Clamp Points (per REA PE-80)
DC.
2kV/S.
µ
100V/
S
µ
10kV/
S
µ
Vent Safe @ 100V/
S
DC Impulse Current (8x20
AC Discharge Current (60Hz/1S)
DC Holdover (per IEEE 465.1)
Measurement
3 Electrode Gas Tube
1.0
to Ground Max.
Per UL 497
1.0A 100 Sec. Max.
350VDC Max.
400VDC Max.
500VDC Max.
800VDC Max.
1600VDC Max.
µ
S wave)
10KA Nom.
10A Nom.
160VDC Max.
®