3-12
Coral IPx 800 Installation Manual
Do the following:
a. If the second message appears, the system initialized properly and is capable of
processing calls. The version number of the generic feature software is indicated
where the x's appear in the line that reads
CCS xx.xx.xx.
b. If the version number shown on the PI does not match the version number
printed on the IMC8/IMC16 flash card supplied with the system, perform the
procedure described in Section 4.1 - Generic Feature Software Upgrade
4-1, to install a new generic software version on the IMC8/IMC16 card.
18. Turn OFF (downwards) the power switch on the front panel of the PS19.
19. If the MAP/CLA and or the DBM/DBX cards are not used in the system, skip to
Step 27
20. Remove the MEX-IP2 card from it's slot and place it on a static protective surface.
21. Some Coral systems may require a DBM baby card to provide additional database
memory storage for a large or complex configuration.
a. If a DBM card is supplied with the system, install a DBM baby card on the
MEX-IP2 card. See
b. Carefully remove the plastic insulation from under the top contact of the
lithium battery holder on the MEX-IP2 card (refer to
22. If a MAP/CLA card is supplied with the system, install the MAP/CLA baby card
on the MEX-IP2 card (refer to
details).
23. Verify that the plastic insulator protecting the top contact of the battery holder on
the MEX-IP2 and DBX cards are removed. See
24. Insert the MEX-IP2 card fully into its card slot in the main cage.
25. Verify that the DIP switches on the front panel of the MEX-IP2 are set to the right.
26. Attach the Program Interface (PI) device cable to the KB0 programming port
connector on front panel of MEX-IP2. Verify that the PI device is configured as in
Step 12
27. Insert the HDC card fully into its card slot in the main cage.
28. In the main cage, turn ON the PS19 power switch, and verify that the green
Power indicator is lit, while the red Alarm indicator is not lit.
If the red alarm indicator illuminates, see:
page 7-13, Troubleshooting (PS19
page 7-33, Troubleshooting (PS19
page 7-49, Troubleshooting (PS19
29. On the front panel of the MEX-IP2, verify that the decimal point (green LED) in
the numeric display illuminates.
Section 8.2, MEX-IP2 on page 8-5
and see
Figure 3-4
DC),
DC-D),
AC), in Chapter 7.
for details.
Figure
3-2).
Section 8.7, MAP on page 8-15
and
Figure 3-2
Figure
3-5.
on page
for