Determining the Cause of the Alarm Indicator
The red Alarm indicator can be activated by malfunctions in the PS19 DC-D or one
of the peripheral shelf cards. The Troubleshooting procedures for a lit Alarm indicator
are described below, depending on the PS19 DC-D usage: Redundant, Double Power
or Economical.
Double Power PS19 DC-D Configuration
For a single PS19 DC-D supplying power only to its own cage the peripheral
cards must be individually examined.
Turn the PS19 DC-D power switch OFF (turn the switch downwards).
1.
2.
Disconnect the expansion cable(s) connected to the relevant cage.
3.
Remove all cards from the relevant cage so that they protrude from the cage by
approximately 1 inch (2.5 cm).
4.
Switch ON the PS19 DC-D and check the red Alarm indicator.
If the Alarm indicator is lit, either the PS19 DC-D is malfunctioning or the
problem is caused by the backplane. Replace the PS19 DC-D unit.
If the Power indicator lights but the Alarm indicator is not lit, the unit is
functioning properly and the alarm is being caused by one of the cards.
5.
For cages that include common control cards (see table below).
Cage
IPx 800M
IPx 800X
To determine which control card is causing the problem, turn the PS19 DC-D
power switch OFF again (turn the switch downwards), re-insert the control card.
Then turn the PS19 DC-D power switch ON, and check the red Alarm indicator.
Continue this process, adding one common control card at a time, and turning
OFF the PS19 DC-D power switch before inserting each card. Turn the PS19 DC-D
power switch ON and check the red Alarm indicator after inserting each card. If
the red Alarm indicator is lit on, the last card inserted is causing the problem and
should be replaced.
Turn the PS19 DC-D power switch OFF, insert the common control cards
(MEX-IP2, HDC, or PX). Then turn the PS19 DC-D power switch ON and check
the red Alarm indicator once again. If the red Alarm indicator is off, the problem
is caused by one of the cards that was removed.
6.
To determine which shared service and peripheral card is causing the problem,
insert the cards into their appropriate slots, one by one, beginning from the right