PROFINET IO (Communication Option 1)

The PROFINET IO interface (Communication Option 1) is an addendum to the already
incorporated LAN/Ethernet communication (Standard Communication Option 0). Endurance
PROFINET IO takes place over the existing LAN/Ethernet communication hardware, see
chapter 3.2, Electrical Specifications on page 8. An extra implemented software stack
guarantees the PROFINET IO communication functionality. That extra SW stack operates fully
independant of the standard LAN/Ethernet protocol stack and allows a common use of both
protocols over the same hardware.

8.7.1. Description

The Endurance PROFINET IO module maps the object temperature, internal temperature and
the status of the pyrometer via PROFINET IO. Furthermore, PROFINET IO allows you to
change a subset of sensor parameters in data exchange mode. In the initialization phase, the
Endurance PROFINET determines the physical structure of the node and creates a local
process image with pyrometer.
The diagnostics concept based on channel specific diagnostic messages, which are mapped
to the respective alarms. Coding standard is according to IEC 61158 PROFINET IO.
The Endurance PROFINET IO module characteristics are:

8.7.2. I/O Device Configuration

The Endurance PROFINET takes over the task of the I/O device in PROFINET IO. Selecting
the I/O module for the process data exchange and defining the time pattern happens during the
I/O controller configuration. The configuration and parameter setting of the Endurance
PROFINET based upon the device's GSD (Generic Station Description) file.
Under PROFINET IO, the device manufacturer describes the device features in a GSD file,
which is XML (Extensible Markup Language) coded and supplied to the end-user.
The Endurance PROFINET device GSD file is:
The Endurance PROFINET IO device configuration is in accordance with the physical
arrangement of the node (slot oriented).
Module slot 0 contains the Endurance PROFINET in its function as station substitute. It does
not deliver process data itself, but provides the parameters required to perform communication
settings of the I/O device (e.g. update cycle time).
Slot 1 (Input/Output module) reflects the physical arrangement of the pyrometer, that deliver a
part of the process and diagnostics data. All specific information on the relevant module is
contained in the associated GSD file.
1.800.561.8187
52
Conformance class: A
Real-Time class: 1 (RT) and the Real-Time class UDP
Connection: 1 x M12
Transfer speed of up to 100Mbit/s full-duplex, also with autonegotiation
I/O update cycle time from 1 ms.
Configurable substitute value behavior in the event of error/failure
8.7.2.1. GSD File
GSDML-V2.25-FlukeProcessInstruments-Endurance-20160616.xml
8.7.2.2. Configuration