  • Page 1 MultiFiber ™ Optical Power Meter and Fiber Test Kits Users Manual May 2012, Rev. 3 8/2015 ©2012-2015 Fluke Corporation All product names are trademarks of their respective companies.
  • Page 2 90 days, unless otherwise stated. Ni-Cad, Ni-MH and Li-Ion batteries, cables or other peripherals are all considered parts or accessories. The warranty extends only to the original buyer or end user customer of a Fluke Networks authorized reseller, and does not apply to any product which, in Fluke Networks’...
  • Page 3: Table Of Contents

    Contents Title Page Introduction ..................................1 Registration ................................... 1 The Fluke Networks Knowledge Base ..........................1 Contacting Fluke Networks ..............................2  Safety Information ................................. 2 Kit Contents ................................... 4 Battery Installation, Life, and Status ............................ 4 Keys and Connectors ................................5 Display Features ..................................
  • Page 4 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual How to Measure Optical Power ............................12 Power Measurements on 8- and 10-Fiber Cables ......................15 How to Measure Loss ................................16 Measure the Loss of Your Test Cords ..........................16 Set the Limit for Loss Measurements ..........................
  • Page 5 Contents Specifications ..................................32 Environmental ................................32 Meter ....................................33 Sources .................................... 35 Calibration Cycle ................................36 1 year ....................................36 Appendix A: Polarities for MTP/MPO Connections ......................37 Appendix B: Reference and Test Connections ........................41...
  • Page 6 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual...
  • Page 7 List of Figures Figure Page Installing the Batteries............................4 Meter and Source Features ..........................5 Meter Display Features ............................6 Source Display Features ............................8 How to Use the OneClick Cleaner for MTP/MPO Connectors ................12 Connections for Power Measurements........................ 13 Power Measurement Display..........................
  • Page 8 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Figure Page A-2. Connections for the Corning Plug & Play Universal Systems Method..............39 ™ B-1. Reference Connections for Multimode Permanent Links with Unpinned MTP/MPO Connectors ....42 Connections for Loss Measurements on Type A Multimode Permanent Links ...
  • Page 9 List of Figures Figure Page Connections Loss Measurements on Type C Multimode Permanent Links  B-12. with Pinned MTP/MPO Connectors........................53 Connections for Loss Measurements on Multimode Permanent Links with Pinned  B-13. MTP/MPO Connectors when Links are Used with Corning Plug & Play Universal Systems......
  • Page 10 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual viii...
  • Page 11: Introduction

    To register, ® go to the Fluke Networks website and click Sign In. In one test, the meter measures optical power or power loss on 12 fibers at one wavelength. The test results include the The Fluke Networks Knowledge Base polarity of the connections (A, B, C, or other).
  • Page 12: Contacting Fluke Networks

    MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual  Warning: Class 1 laser. Risk of eye damage from hazardous radiation.  Do not put products containing circuit boards into the garbage. Dispose of circuits boards in accordance with local regulations.
  • Page 13  Use only replacement parts that are approved by  Do not disassemble or crush battery cells and Fluke Networks. battery packs.  Do not use the Product around explosive gas,  Do not put battery cells and battery packs near vapor, or in damp or wet environments.
  • Page 14: Kit Contents

    Caution To prevent damage to fiber connectors, to For a list of the contents of your MultiFiber Pro kit, see the prevent data loss, and to ensure maximum list that came in the product’s box or see the lists of models accuracy of test results: and accessories on the Fluke Networks website.
  • Page 15: Keys And Connectors

    Keys and Connectors Keys and Connectors   : On/off key.     : Softkeys. The function for each key shows above the key. For access to user preferences, hold   down for 2.5 seconds. See "How to Change User Preferences"...
  • Page 16: Display Features

    MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Display Features  Modes for the meter and settings for tests. To select the POWER, SET REF, or LOSS measurement  modes, press . To change settings for measurements ...
  • Page 17 Display Features    POLARITY: The polarity of the connections between the DELETE: In VIEW RECORD mode, use DELETE to meter and source: delete the selected record or all records. See "Delete Records" on page 26.  A, B, C: The connections use a standard method, A, B, ...
  • Page 18 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual   AUTO shows when the source transmits a wavelength identifier, and the meter changes its wavelength setting to agree with the source. When    only shows, you must press on the meter to select the correct wavelength.
  • Page 19: How To Change User Preferences

    : ON: The source transmits a wavelength To set user preferences for the meter or source identifier that a MultiFiber Pro meter can read. For the meter: Make sure the meter is in power or loss OFF: The source does not transmit a wavelength measurement mode.
  • Page 20: Polarity Detection

    Polarity Detection Table 2. User Preferences Setting Choices You can use the MultiFiber Pro meter and source to see the polarity of MTP/MPO patch cords and cables. The signals Turn the backlight off or on.  from the source include the channel numbers. The meter...
  • Page 21: Auto Wavelength Function

    Fluke Networks recommends that  press to make 2 kHz show. you use a mechanical cleaner, such as the Fluke Networks ™ OneClick Cleaner, to clean connectors.  To save the setting and exit setup mode, hold down for 2.5 seconds.
  • Page 22: How To Measure Optical Power

    MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual How to Measure Optical Power CLICK! A power measurement shows the optical power level from a source such as an optical network interface card or optical test equipment. The meter can show power measurements in watts or dBm.
  • Page 23 2 kHz flashes and you cannot save measurements if Measuring the power the meter is connected to a MultiFiber Pro source of a source that is set to 2 kHz mode. To save the measurements, make sure the meter has ...
  • Page 24 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual  The difference (in dB) between the level of power on each channel and the maximum power of all 12 channels: No ovals Max. At regular intervals, the meter finds the maximum power level again and adjusts the bargraphs as necessary.
  • Page 25: Power Measurements On 8- And 10-Fiber Cables

    How to Measure Optical Power  UNIV: Shows when modules have the Corning Plug &   AUTO shows when the source transmits a Play Universal Systems method of polarity wavelength identifier and the meter changes its ™ management. See Figure B-16 on page 57. wavelength setting to agree with the source.
  • Page 26: How To Measure Loss

    MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual How to Measure Loss Set the Limit for Loss Measurements The meter compares loss measurements to a limit to give a The loss measurement shows how much optical power is lost ...
  • Page 27: About The Reference

    How to Measure Loss About the Reference For singlemode links with APC connectors, you must use Type A test cords and adapters. Type A The reference is the baseline power level for loss components correctly align the angles in the measurements.
  • Page 28 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual  If a power level is lower than -27.5 dBm (1.78 μW) or if Caution   show, look for these problems: If you disconnect test cord 1 from the source after you set the reference, you must set the ...
  • Page 29 How to Measure Loss Type B Test cord 1 Pinned/Pinned  Caution  Do not disconnect test Use one test cord to set cord 1 from the source the reference. after you set the reference. Meter Source  Disconnect test cord 1 Type B...
  • Page 30: Measure Loss

    MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual  MODE: 2 kHz does not show Measure Loss  On the meter, press to make LOSS show. Figure Set the reference as described on page 17. Figure 10 on page 22 shows the display for loss Make sure the limit is correct.
  • Page 31 How to Measure Loss Pinned/Unpinned Unpinned/Pinned Type A adapter Type A adapter Type A Key-down/Key-up Key-down/Key-up Fiber link Type B Type B Testcord 2 Test cord1 Pinned/Pinned Pinned/Pinned  Caution Do not disconnect test cord 1 from the source after you set Meter shows...
  • Page 32 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual  The levels of power loss relative to the limit you set: <25% <50% <75% <100% 100%  When all ovals are below the line for a channel, the measurement for that channel is below the limit you set.
  • Page 33: Loss Measurements On 8- And 10-Fiber Cables

    How to Measure Loss  POLARITY ?: The connections do not use a standard  These sections switch between the wavelength that method, one or more fibers are not connected, or the meter measures (nm shows) and the record SCAN ALL is off on the source. number for the next record you save (RECORD shows).
  • Page 34: How To Identify Cables Or Fibers

    MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual How to Identify Cables or Fibers Negative loss can be caused by the following:  The fiber ends were dirty when you set the reference. You can use the 2 kHz modulated signal from the source to identify cables or fibers at patch panels.
  • Page 35: Memory Functions

    Memory Functions   If memory is full, the meter shows when you Note try to save measurements. The source’s auto wavelength function does not operate when you use 2 kHz mode. View Records To identify cables, use an MTP/MPO cable to connect the ...
  • Page 36: Delete Records

    MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Delete Records To delete all the records in memory   You can delete one set of 12 records, or you can delete all Hold down until the setup menu shows, press the records in memory.
  • Page 37 Memory Functions  The relative level of power or power loss measured on the channel. For loss measurements, the limit line and  OK or show. See Figure 7 on page 14 and Figure 10 on page 22 for descriptions of these measurements. ...
  • Page 38: Upload Records To A Pc

    MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual To use LinkWare PC software to delete all the records in Enter project information, then click OK. memory Import all records from the meter or select records to import.
  • Page 39: Maintenance

     Use only specified replacement parts for user- replaceable items.  Use only Fluke Networks authorized service centers. Clean the Meter and Source Clean the display with glass cleaner and a soft, lint-free cloth. Clean the case with a soft cloth dampened with water or water and a mild soap.
  • Page 40: See The Software Version And Calibration Date

    MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual See the Software Version and Calibration Update the Software Date  Caution The displays can show the software versions for the meter To prevent unexpected loss of power when you and source and the calibration date for the meter.
  • Page 41: Options And Accessories

    Options and Accessories Connect the meter or source to the PC with the USB cable provided, as shown in Figure 12. On the LinkWare PC menu, select Utilities > MultiFiber Pro > Software Update, find and select the update file, then click Open.
  • Page 42: Specifications

    MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Specifications Environmental Operating temperature -10ºC to +50ºC Storage temperature -20ºC to +50ºC Operating humidity 95% (10ºC to +35ºC) non-condensing 75% (35ºC to +50ºC) non-condensing Uncontrolled <10ºC Operating altitude 4,000 m...
  • Page 43: Meter

    Specifications Meter Specifications apply at 23ºC (73ºF), unless otherwise noted. Detector type InGaAs Calibrated wavelengths 850 nm, 1300 nm, 1310 nm, 1550 nm Measurement range 0 dBm to -50 dBm Test time 6 seconds Power measurement linearity ±0.1 dB Power measurement uncertainty ±0.35 dB Power measurement repeatability <...
  • Page 44 5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm) Weight 10.9 oz (309 g)  3. Measured power levels 0 dBm. Backlight on. Battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries.
  • Page 45: Sources

    Specifications Sources Specifications apply at 23ºC (73ºF), unless otherwise noted. 850 nm Source 1310 nm Source 1550 nm Source Emitter type Laser Wavelength ±30 nm 1310 nm ±20 nm 1550 nm ±20 nm Spectral width (FWHM) 50 nm (typical) 2 nm typical, 5 nm maximum ...
  • Page 46: Calibration Cycle

    5.8 in x 3.2 in x 1.6 in (14.7 cm x 8.0 cm x 4.0 cm) Weight 11.4 oz (323 g) 6. Auto wavelength, SCAN ALL, and backlight on. Battery life depends on the condition and type of batteries used. Fluke Networks recommends alkaline batteries. Calibration Cycle...
  • Page 47: Appendix A: Polarities For Mtp/Mpo Connections

    Appendix A: Polarities for MTP/MPO Connections Figure A-1 on page 38 shows the end-to-end connections The meter shows UNIV for the Corning Plug & Play ™ made by type A, B, and C cables with MTP/MPO connectors. Universal Systems method of polarity management. See The POLARITY indication on the meter shows A, B, C for Figure B-16 on page 57.
  • Page 48 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Type A Source channel: 9 10 11 12 Meter channel: 9 10 11 12 Type B Source channel: 9 10 11 12 Meter channel: 12 11 10 9 Type C...
  • Page 49 Polarities for MTP/MPO Connections Pinned MTP/MPO connector Signal paths inside the module MTP/MPO connector: 9 10 11 12 Single-fiber connectors: 9 11 12 10 8 GUE28.EPS Figure A-2. Connections for the Corning Plug & Play Universal Systems Method ™...
  • Page 50 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual...
  • Page 51: Appendix B: Reference And Test Connections

    Appendix B: Reference and Test Connections  Caution This appendix shows the connections to make to set the reference and measure loss on MTP/MPO links with pinned For singlemode links with APC connectors, you and unpinned connectors. must use Type A test cords and adapters. Type A components correctly align the angles in the connectors.
  • Page 52 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Type B Test cord 1 Pinned/Pinned  Caution  Use one test cord to Do not disconnect test set the reference. cord 1 from the source after you set the reference.
  • Page 53 Appendix B: Reference and Test Connections Pinned/Unpinned Unpinned/Pinned Type A adapter Type A adapter Type A Key-down/Key-up Key-down/Key-up Fiber link Type B Type B Test cord 2 Test cord 1 Pinned/Pinned Pinned/Pinned  Caution Do not disconnect test cord 1 from the source after you set the Meter shows...
  • Page 54 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Pinned/Unpinned Unpinned/Pinned Type B adapter Type B adapter Type B Key-up/Key-up Key-up/Key-up Fiber link Type B Type B Test cord 2 Test cord 1 Pinned/Pinned Pinned/Pinned  Caution Do not disconnect test cord 1 from the source after you set the Meter shows...
  • Page 55 Appendix B: Reference and Test Connections Pinned/Unpinned Unpinned/Pinned Type A adapter Type A adapter Type C Key-down/Key-up Key-down/Key-up Fiber link Type B Type B Test cord 2 Test cord 1 Pinned/Pinned Pinned/Pinned  Caution Do not disconnect test cord 1 from the source after you set the Meter shows...
  • Page 56 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Type B Test cord 1 Pinned/Pinned  Caution  Use one test cord to set Do not disconnect test the reference. cord 1 from the source after you set the reference.
  • Page 57 Appendix B: Reference and Test Connections Unpinned/Pinned Unpinned/Pinned Type A adapter Type A adapter (A) Type A Key-down/Key-up Key-down/Key-up Fiber link Type B Type B Test cord 2 Test cord 1 Pinned/Unpinned Pinned/Pinned  Caution Do not disconnect test cord 1 from the source after you set the Meter shows...
  • Page 58 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Unpinned/Pinned Unpinned/Pinned Type B adapter Type B adapter Type B Key-up/Key-up Key-up/Key-up Fiber link Type B Type B Test cord 2 Test cord 1 Pinned/Unpinned Pinned/Pinned  Caution Do not disconnect test cord 1 from the source after you set the Meter shows...
  • Page 59 Appendix B: Reference and Test Connections Unpinned/Pinned Unpinned/Pinned Type A adapter Type A adapter Type C Key-down/Key-up Key-down/Key-up Fiber link Type B Type B Test cord 2 Test cord 1 Pinned/Unpinned Pinned/Pinned  Caution Do not disconnect test cord 1 from the source after you set the Meter shows...
  • Page 60 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Type B Type B Test cord 2 Test cord 1 Type B adapter Pinned/Unpinned Pinned/Pinned Key-up/Key-up  Caution  Use two test cords Do not disconnect test and one adapter to cord 1 from the source set the reference.
  • Page 61 Appendix B: Reference and Test Connections Type B Test cord 3, Unpinned/Unpinned Unpinned/Pinned Pinned Pinned Type A adapter Type A adapter Type B adapter Type A Key-down/Key-up Key-down/ Key-up/ Fiber link Key-up Key-up Type B Type B Test cord 2 Test cord 1 Pinned/Unpinned Pinned/Pinned...
  • Page 62 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Type B Test cord 3 Unpinned/Unpinned Unpinned/Pinned Pinned Pinned Type B adapter Type B adapter Type B adapter Type B Key-up/Key-up Key-up/ Key-up/ Fiber link Key-up Key-up Type B...
  • Page 63 Appendix B: Reference and Test Connections Type B Test cord 3 Unpinned/Pinned Unpinned/Unpinned Pinned Pinned Type A adapter Type A adapter Type B adapter Type C Key-down/Key-up Key-down/Key-up Key-up/ Fiber link Key-up Type B Type B Test cord 2 Test cord1 Pinned/Unpinned Pinned/Pinned ...
  • Page 64 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Type B Test cord 3 Unpinned/Pinned Unpinned/Unpinned Pinned Pinned Type A adapter Type A adapter Type B adapter Type B Key-up/Key-down Key-up/ Key-up/ Fiber link Key-down Key-up Type B...
  • Page 65 Appendix B: Reference and Test Connections Type B Type B Test cord 2 Test cord 1 Type B adapter Pinned/Unpinned Pinned/Pinned Key-up/Key-up  Caution Do not disconnect test  Use two test cords and cord 1 from the source one adapter to set the after you set the reference.
  • Page 66 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual Unpinned/Pinned Pinned Unpinned Breakout Type B adapter cable Key-up/Key-up Straight-through Type B Type B Test cord 2 Test cord 1 Pinned/Unpinned Pinned/Pinned  Caution Do not disconnect test cord 1 from Meter shows...
  • Page 67 Appendix B: Reference and Test Connections Unpinned/Pinned Pinned Unpinned Type B adapter Key-up/Key-up Breakout cable Signal paths Type B Type B inside the module Test cord Test cord Pinned/Unpinned Pinned/Pinned  Caution Do not disconnect test cord 1 from Meter shows the source after you set the UNIV reference.
  • Page 68 MultiFiber Pro Optical Power Meter and Fiber Test Kits Users Manual...

Table of Contents