Vacmaster VWMB508 0101 Operator's Manual page 9

Wall mount
Hide thumbs Also See for VWMB508 0101:
Table of Contents

Advertisement

IMPORTANT! WALL MOUNT RACK AND STORAGE ASSEMBLY
Do not mount the rack over 5 ft / 1.5 m from the floor.
Do not screw the rack to drywall only. Secure the screws to a stud.
Do not hang from or sit on the wall mount rack.
Do not exceed the 40 lb / 18 kg maximum weight limit.
8. Locate a wall stud that is not more than 18 ft / 5.5 m away from an electrical outlet. Align the
three screw holes on the wall mount rack so that they are over the stud. Make sure the rack
is level and mark the hole locations. Make a 1/8 in. diameter pilot hole in each marked location.
Secure the wall mount rack to the wall stud with the three screws provided (Fig. 8).
MOUNTING THE VACUUM ONTO THE RACK
1. Your vacuum comes ready for dry vacuum cleaning. If the cartridge filter is not installed, refer to
page 15 for installation instructions (Fig. 9 & 10).
2. For wet vacuum cleaning, remove the cartridge filter, and install the supplied foam wet filter.
See page 15 for the foam wet filter installation instructions (Fig. 11).
3. Place the power head back on the collection tank, and secure into place using the 2 side
latches (Fig. 12 & 13).
4. Mount the vacuum onto the wall mount rack by aligning the hanging hook on the rear of the
vacuum with the slot on the wall mount rack and slide downward until it locks (Fig. 14).
5. Wind the excess power cord around the cord storage hook located on the side of the vacuum
(Fig. 15).
6. Insert the locking end of the hose into the vacuum port of the collection tank and turn clockwise
to lock into place (Fig. 16).
7. Choose the desired accessory, such as the remote control handle, and insert onto the end of
the hose or extension wand (Fig. 17).
POLARIZED PLUG
To reduce the risk of electrical shock, this appliance has a polarized plug (one blade wider than the
other). This plug will fit in a polarized outlet only one way. If the plug does not fit fully in the outlet,
reverse the plug. If it still does not fit, contact a qualified electrician to install the proper outlet.
Do not change the plug in any way. Double insulation
grounded power cord and grounded power supply system.
DISMOUNTING THE VACUUM FROM THE RACK
1. Disconnect the power cord from the electrical outlet (Fig. 18).
2. Lift the vacuum up and out of the rack by the handle (Fig. 19).
eliminates the need for the three wire
9

Advertisement

Table of Contents
loading

Table of Contents