Vacmaster VWMB508 0101 Operator's Manual

Vacmaster VWMB508 0101 Operator's Manual

Wall mount
Hide thumbs Also See for VWMB508 0101:

Advertisement

Quick Links

Wet/Dry Vacuum
Operator's Manual
Wall Mount Wet/Dry Vacuum
Model No.
VWMB508 0101
FOR YOUR SAFETY
Read and understand this manual before use.
Keep this manual for future reference.
Distributed By
Replacement Filters &
Cleva North America, Inc.
Accessories available at:
601 Regent Park Court
Vacmaster.com
Greenville, SC 29607

Advertisement

Table of Contents
loading

Summary of Contents for Vacmaster VWMB508 0101

  • Page 1 Wet/Dry Vacuum Operator’s Manual Wall Mount Wet/Dry Vacuum Model No. VWMB508 0101 FOR YOUR SAFETY Read and understand this manual before use. Keep this manual for future reference. Distributed By Replacement Filters & Cleva North America, Inc. Accessories available at: 601 Regent Park Court Vacmaster.com...
  • Page 2: Table Of Contents

    FOR YOUR SAFETY: CAREFULLY READ AND UNDERSTAND ALL INSTRUCTIONS. WARRANTY We take pride in producing a high quality, durable product. This Vacmaster® product carries a limited two (2) year warranty against defects in workmanship and materials from date of purchase under normal household use.
  • Page 3: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE USING THIS VACUUM. Read and understand this operator’s manual and all labels on the Wet/Dry Vacuum cleaner before operating. Safety is a combination of common sense, staying alert and knowing how your vacuum works.
  • Page 4 When using as blower: • Direct air discharge only at work area. • Do not use Wet/Dry Vac as a sprayer. • Do not direct air at bystanders. • Keep children away when blowing. • Wear safety goggles. FCC COMPLIANCE: This device complies with part 15 of the FCC Rules.
  • Page 5: Double Insulation Instructions

    DOUBLE INSULATION INSTRUCTIONS This Wet/Dry Vacuum is double-insulated, eliminating the need for a separate grounding system. Use only identical replacement parts. Read the instructions for Servicing Double-Insulated Wet/Dry Vacuum before servicing. Use this Wet/Dry Vacuum as described in this manual. Observe the following warnings that appear on the motor housing of your Wet/Dry Vac.
  • Page 6: Extension Cords

    EXTENSION CORDS When using an extension cord with your Wet/Dry Vacuum refer to the following table to determine the required A.W.G. wire size. Before using the cleaner make sure the power cord and extension cord are in good working condition. Make repairs or replacements before using the vacuum cleaner.
  • Page 7: Unpacking & Checking Carton Contents

    UNPACKING & CHECKING CARTON CONTENTS Remove all contents from the box. Remove the power head and take out any contents inside the collection tank. Check each item against the carton contents list. Carton Contents List: Key Description ..………………….…..Qty. Hose Storage Rack …………... Hose Storage Support ……...…..
  • Page 8: General Assembly Instructions

    (Fig. 6). 7. Insert the steel rod with hose storage rack into the two holes located on the top of the wall mount rack. Ensure the Vacmaster logo is facing forward (Fig. 7).
  • Page 9 IMPORTANT! WALL MOUNT RACK AND STORAGE ASSEMBLY • Do not mount the rack over 5 ft / 1.5 m from the floor. • Do not screw the rack to drywall only. Secure the screws to a stud. • Do not hang from or sit on the wall mount rack. •...
  • Page 10: Dry Vacuum Operation

    DRY VACUUM OPERATION DRY VACUUMING WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION ENTITLED “IMPORTANT SAFETY INSTRUCTIONS”. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO: LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASED PAINTS, GASOLINE, ALCOHOL, OR AEROSOL SPRAYS.
  • Page 11: Liquid Vacuum Operation

    OPERATING INSTRUCTIONS: DRY VACUUMING 5. Insert the locking end of the hose into the vacuum port and turn to lock into place. Choose the desired accessory and insert onto the end of the hose or extension wand (Fig. 5). 6. Verify that the switch is in the 'O' (OFF) position before plugging the power cord into the outlet (Fig.
  • Page 12 OPERATING INSTRUCTIONS: WET VACUUMING 3. Push the required attachment onto the free end of the hose or extension wand (Fig. 3). 4. Ensure that the on/off switch is in the ‘O’ OFF position before plugging the power cord into the outlet (Fig.
  • Page 13: Blower Operation

    BLOWER OPERATION This Wet/Dry Vacuum has blowing capabilities. To use the blower feature follow the instructions listed. WARNING: ALWAYS WEAR SAFETY GOGGLES COMPLYING WITH ANSI Z87.1 (OR IN CANADA, CSAZ94.3) BEFORE USING BLOWER. WARNING: KEEP BYSTANDERS CLEAR FROM BLOWING DEBRIS. WARNING: WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT BE INHALED.
  • Page 14: Maintenance

    MAINTENANCE EMPTYING THE COLLECTION TANK WARNING: ALWAYS DISCONNECT THE PLUG FROM THE POWER OUTLET BEFORE REMOVING THE POWER HEAD FROM COLLECTION TANK. 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2. Disconnect the hose from the vacuum (Fig. 2). 3.
  • Page 15: Installing & Cleaning Cartridge Filter

    INSTALLING & CLEANING CARTRIDGE FILTER INSTALLING CARTRIDGE FILTER 1. Verify that the power cord is disconnected from the outlet (Fig. 1). 2. Remove the power head and place in upside down position. 3. Install the cartridge filter over the filter cage making sure the cage is completely covered. Carefully push filter in until it stops against the power head (Fig.
  • Page 16: Resetting The Remote Control

    CLEANING FOAM WET FILTER 1. With the removed power head in an upside down position, carefully remove the foam wet filter (Fig. 4). 2. Use a mild soap and water solution to wash the foam wet filter and rinse with clean water (Fig. 5). 3.
  • Page 17: Troubleshooting

    TROUBLESHOOTING WARNING! TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE TROUBLESHOOTING. PROBLEM POSSIBLE CAUSE SOLUTION Check the power supply, cord, No power supply. breakers, and fuses. Unplug and check the power Faulty power cord. cord. If damaged, have it The wet/dry vacuum will not repaired by a professional.
  • Page 18: Exploded View

    EXPLODED VIEW...
  • Page 19: Parts List

    PARTS LIST Part Part Number Description Quantity Power Head Assembly Collection Tank 551001176 Latch Assembly 551001153 Vacuum Port Assembly 551001177 Bumper Foot 551001178 Hose Storage Rack 551001179 Hose Storage Support 551001180 Wall Mount Rack 551001181 Accessory Storage Rack 551001141 Foam Wet Filter 551301101 Cartridge Filter 551001182...

Table of Contents