Figure 2-9. Emergency AC Power Feed (All GENs INOP)
EMERGENCY AC SYSTEM
The emergency AC power system provides
115-/200-volt, 3-phase, 400-Hz AC power au-
tomatically in flight in the event of loss of all
primary and auxiliary AC power. The air-
driven generator (ADG) is stowed in a com-
partment on the right side of the nose (Figure
2-10) and can be deployed either automatically
or manually. Once deployed, the ADG cannot
be retracted until the airplane is on the ground.
When deployed, the ADG provides power di-
rectly to the ADG bus. ADG power is rated at
15 kva and is controlled through a GCU also
rated at 15 kva.
The ADG consists of a ram-air turbine (RAT)
and an AC electrical generator mounted on a
trunnion-pivoted support leg. The ram-air tur-
bine is a two-bladed 19-inch propeller (Figure
2-11) with a variable-pitch mechanism that is
used to achieve the constant speed necessary to
operate the generator at a constant frequency.
2-8 CL 601-3A/R
APU
APU
GEN
GEN
AP/EP
GCU
GCU
MONITOR
MONITOR
CONT
GTC
1
B23
ESS
PWR
TC
ADG BUS
C5
EMERG
AC
TC
3B
FOR TRAINING PURPOSES ONLY
FlightSafety Canada
CL-600-2B16 PILOT TRAINING MANUAL
EXT
EXT
IDG
IDG
ADG
ADG
AC
AC
GCU
GCU
GCU
GCU
GTC
2
GLC
2
MAIN AC BUS 2
Figure 2-10. Air-Driven Generator Location
The AC generator is similar in construction
and operation to the other three generators but
is rated at 15 kva. It is air cooled and therefore
subject to lower temperature restrictions.
2
2
LEGEND
UNPOWERED
POWERED BUS
ADG POWER