LEFT COLLECTOR TANK
JET PUMP
BOOST PUMP
ON
INOP
TO RIGHT COLLECTOR TANK
FIREWALL
SOV'S
TO APU FUEL LINE
ECOLOGY TANK
JET PUMP MOTIVE FLOW FUEL
LOW
PRESS
LP PUMP
LEGEND
14TH-STAGE
SUPPLY
AIR IN
LP PUMP PRESSURE
HP PUMP PRESSURE
SIGNAL/CONTROL
ECOLOGY DRAIN
ECOLOGY RETURN
OIL
AIR
ELECTRICAL
MECHANICAL
INLET
STATOR
GUIDE
VANES
FEEDBACK
LINK
P 3 T 2 C
VALVE
CLOSED
FILTER
BYPASS
BYPASS
HP PUMP
PUMP BYPASS
FILTER
FUEL
AIR
HEATER
OUT
Figure 7-7. Fuel System Schematic
COMBUSTOR
VANES
18
INJECTORS
18 FUEL HOSES
VARIABLE
GEOMETRY
FUEL FLOW
ACTUATORS
DISTRIBUTOR
DRAIN VALVE
N 2
BYPASS
BYPASS
VALVE
FCU
AMPLIFIER
TORQUE
N 1
MOTOR
T 2
FUEL TEMP
INDICATOR
FUEL
FLOW
4000
3500
3000
2000
1000
P
800
P
H
600
400
200
0
L
R
x10
FUEL FLOW
OIL OUT
OIL
COOLER
OIL IN
THROTTLE
LEVER
TRANSDUCER
N 2