INDICATION
A red DUCT FAIL light (Annunciator Panel
section) is located on the center instrument
panel. This light will flash as a master warn-
ing to alert the crew to a bleed-air leak.
At the same time, a steady red DUCT FAIL
light in one of the engine bleed-air switchlights
(Figure 9-1) or a single red DUCT FAIL light
in the wing anti-ice system will illuminate to
indicate the failed area.
Additional indication of a bleed-air leak lo-
cation is provided by the BLEED-AIR LEAK
annunciator panel located behind the copilot
(Figure 9-12). Each magnetic indicator iden-
tifies a specific section of the duct to pinpoint
a leak. Normally, the indicators show black
and, when tripped, they will show black and
white triangles. An indicator RESET switch
is provided to reset any tripped indicator.
TESTING
A SYSTEM TEST button located on the
BLEED-AIR LEAK annunciator panel, when
pushed, will (1) simultaneously trip all indi-
cators, (2) illuminate the flashing DUCT FAIL
light, (3) illuminate the DUCT FAIL lights in
the engine bleed-air switchlights (4 lights), and
(4) illuminate the DUCT FAIL light on the
ANTI-ICE control panel.
Releasing the SYSTEM TEST button will ex-
tinguish all DUCT FAIL lights. The magnetic
indicators must be reset by pushing the IND
RESET button which is also located on the
BLEED-AIR LEAK annunciator panel.
CL-600-2B16 PILOT TRAINING MANUAL
FOR TRAINING PURPOSES ONLY
FlightSafety Canada
14 STAGE
RIGHT
LEFT
FUS
RIGHT
LEFT
WING
RIGHT
LEFT
10 STAGE
RIGHT
LEFT
IND RESET
SYSTEM TEST
BLEED AIR LEAK
Figure 9-12. Bleed-Air Leak Annunciator
L t é e
L t d .
NORMAL
TRIPPED
CL 601-3R 9-11