BOMBARDIER Challenger 601-3A CL-600-2B16 Pilot Training Manual page 366

Hide thumbs Also See for Challenger 601-3A CL-600-2B16:
Table of Contents

Advertisement

PRESSURE RELIEF/
BLEED VALVE
OVERFLOW
BOTTLE
CASE
DRAIN
FILTER
RIGHT
ENGINE DRIVEN
PUMP
LEGEND
R ENG
ENGINE DRIVEN
PUMP PRESSURE
ELECTRICAL
PUMP PRESSURE
SUCTION
RETURN
NITROGEN
Figure 13-4. No. 2 Hydraulic System Schematic
CL-600-2B16 PILOT TRAINING MANUAL
HI
RESERVOIR
TEMP
HEAT EXCHANGER/
FAN
RH ENG
FIRE
PUSH
FIREWALL
SHUTOFF VALVE
(MOTOR DRIVEN)
P
PUMP
PRESSURE
SWITCH
FILTER
NO. 2
TO SYSTEMS
Figure 13-5. No. 2 Hydraulic System
FOR TRAINING PURPOSES ONLY
FlightSafety Canada
AC BUS 1
CASE
DRAIN
FILTER
OFF
ON
AC
PUMP
2B
P
ELECT
PUMP
PRESSURE
SWITCH
PRESSURE
RELIEF VALVE
ACCUMULATOR
L t é e
L t d .
ELECTRIC
RETURN
FILTER
PUMP
SWITCH
CL 601-3A/R 13-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Challenger 601-3r cl-600-2b16

Table of Contents