Destination of Data
The KTSync program wedges or downloads barcode data to one of the following
four destinations:
File: The KTSync makes a file name based on 3.11 if file name is specified as an
"sn_timestamp.txt". The default directory is /Users/Shared/KTSyncData directory.
The user may define another directory or another filename by clicking the "New"
button. The maximum file path length is 128 characters.
Internal Viewer: The KTSync displays barcode data in KTSync internal text viewer.
Active Window: The KTSync sends barcode data to current active window if Active
window option is selected.
User Application: The user may define the target application by pressing the "New"
button. The maximum application name path length is 128 characters.
Synchronization Options
Synchronize KDC Clock
KTSync will set the KDC's date and time with Mac PC date and time when the KDC
is connected to Mac, if this option is enabled.
Burst Synchronization
KTSync will synchronize barcode data from KDC in burst mode. Otherwise, KTSync
would synchronize barcode data one by one. This option is enabled by default and
maynot be disabled.
Synchronization on Connection
KTSync will automatically synchronize barcode data from the KDC when the KDC is
connected, if this option is enabled.
Clear KDC Memory After Synchronization
KTSync clears barcode data stored in the KDC's memory once synchronization has
finished, if this option is enabled.
Append Data to File
KTSync appends synchronized data to existing file specified on destination. If file
does not exist then KTSync creates a new file.