AIR-TO-WATER HEAT PUMP
(2). GRS-CQ12Pd/Na-K(O).GRS-CQ14Pd/Na-K(O).GRS-CQ16Pd/Na-K(O)
Silk Screen
AC-L
Live wire input of power supply, red
N
Neutral line input of power supply(PFC blue inductive wire) blue
L1-1
PFC brown inductive wire
PFC yellow inductive wire
L2-1
PFC white inductive wire
L1-2
U-phase of compressor
U
V-phase of compressor
V
W-phase of compressor
W
DC fan
1 pin:strong power supply;3 pin:fan GND;4 pin:+15V;5 pin:control signal;6
DC_MOTOR1
pin:feedback signal;
DC fan
1 pin:strong power supply;3 pin:fan GND;4 pin:+15V;5 pin:control signal;6
DC_MOTOR2
pin:feedback signal;
4-way valve
4V1
Electric heating tape
HEAT
VA-1
E-heater of chassis
HPP
High pressure switch
LPP
Low pressure switch
T-SENSOR2
1, 2hole:pipe temperature;3, 4hole:environment;5, 6hole:exhaust
T-
1 hole:+3.3V
SENSOR3
CN66.CN67
Communication cable 2 pin B,3 pin A
Communication cable 1 pin earthed,2 pin B,3 pin A,4 pin+12 power supply
CN65
It can not be used for communication between outdoor unit and indoor unit.
Pipe electric expansion valve
FA
1-4 pin:driving impulse output;5 pin:+12V;
Signal input of pressure sensor
H-PRESS
1 pin:GND;2 pin:signal input;3 pin:+5V
Specification
2 hole: detection: suction temperature sensor
INSTALLATION