Pcb Outline - Gree GRS-CQ6.0Pd/Na-K Service Manual

Air-to-water heat pump
Table of Contents

Advertisement

AIR-TO-WATER HEAT PUMP

2.2 PCB Outline

(1). GRS-CQ6.0Pd/Na-K(O).GRS-CQ8.0Pd/Na-K(O).GRS-CQ10Pd/Na-K(O)
Silk Screen
AC-L
Live wire input of power supply, red
N
Neutral wire input of power supply, white
E1
Ground wire, yellow green
L2-2
PFC blue inductive wire
L1-1
PFC brown inductive wire
L2-1
PFC yellow inductive wire
L1-2
PFC white inductive wire
U
U-phase of compressor
V
V-phase of compressor
W
W-phase of compressor
DC fan
1 pin:strong power supply;3 pin:fan GND;4 pin:+15V;5 pin:control signal;6
DC_MOTOR1
pin:
feedback signal;
4V 4V1
4-way valve
HEAT
Electric heating tape
VA-1
E-heater of chassis
HPP
High pressure switch
LPP
Low pressure switch
OVC-COMP
Overload protection of compressor
T-SENSOR2
1, 2 hole:pipe temperature;3, 4 hole:environment;5, 6 hole:exhaust
T-
1 hole: +3.3V
SENSOR3
CN66.CN67
Communication cable 2 pin B,3pinA
Communication cable: 1 pin earthed,2 pin B,3 pin A,4 pin+12power supply;
CN65
It can not be used for communication between outdoor unit and indoor unit;
Pipe electric expansion valve
FA
1-4 pin:driving impulse output;5 pin:+12V;
Signal input of pressure sensor
H-PRESS
1 pin:GND;2 pin:signal input;3 pin:+5V
Specification
2 hole: detection ; suction temperature sensor
INSTALLATION
84