Gree GRS-CQ6.0Pd/Na-K Service Manual page 75

Air-to-water heat pump
Table of Contents

Advertisement

AIR-TO-WATER HEAT PUMP
Step3:Attaching indoor unit to the wall make use of accessory expansion
bolt
Expansion bolt
Install wall
C CAUTION!
While lifting the indoor unit, at least two persons should be joined. Weight of
the indoor unit is almost 52kg.
Precautions on Installation of Indoor Unit
Indoor unit shall be vertically mounted on the wall of the room with expansion
bolt.
Keep the Indoor unit away from heat sources such as heat sink and so on in the
room as much as possible.
Keep the indoor unit as close as possible to outdoor unit. Level distance between
connection pipes can not exceed 30m and vertical distance can not exceed 15m.
INSTALLATION
70