Air-to-water heat pump
Table of Contents

Advertisement

AIR-TO-WATER HEAT PUMP
SXVD200LCJ/A-K
SXVD200LCJ/A-M
Litre
coil
specification
coil
M
length
N
D(mm)
D1(mm)
H(mm)
A(mm)
B(mm)
C(mm)
E(mm)
F(mm)
I(mm)
J(mm)
K(mm)
Outline
(Diameter×H)
(mm)
Package
(W*D*H) (mm)
Net
kg
weight
Gross
kg
weight
Connection of Waterway System
If connection between water tank and indoor unit should be through the wall, drill a
holeφ70 for pass of circulating water pipe. It is unnecessary if the hole is not needed.
Preparation of pipelines: Circulating water outlet/inlet pipe must be hot water pipe,
PPR pipe with nominal out diameter of dn25 and S2.5 series (wall thickness of 4.2mm)
being recommended. Cooling water inlet pipe and hot water outlet pipe of water tank
should also be hot water pipe, PPR pipe with nominal out diameter of dn20 and S2.5
series (wall thickness of 3.4mm) being recommended. If other insulated pipes are
adopted, refer to the above dimensions for out diameter and wall thickness.
Installation of circulating water inlet/outlet pipes: Connect the water inlet of unit
with circulating outlet of water tank and water outlet of unit with circulating inlet of
water tank.
Installation of water inlet/outlet pipes of water tank: Safety check valve (→ on the
valve body points at water tank), filter and cut-off valve must be installed for water
inlet pipe according to the installation sketch of unit. At least a cut-off valve is needed
for the water outlet pipe.
Installation of blow-off pipe at the bottom of water tank: Connect a piece of PPR
pipe with drainage outlet to floor drain. A cut-off valve must be installed in the middle
of the drainage pipe and at the place where it is easy to be operated by the users.
SXVD200LCJ2/A-K
SXVD200LCJ2/A-M
200L
200L
\
10m
13m
13m
540
438
1595
272
432
431
\
80
\
247.5
739
Φ540X1595
1620X625X630
68
71
77
80
SXVD300LCJ/A-K
SXVD300LCJ/A-M
300L
SUS304 Ф22X0.8
\
18.5m
105
112
\
\
Φ620X1620
1645X705X710
82
92
INSTALLATION
SXVD300LCJ2/A-K
SXVD300LCJ2/A-M
300L
10m
18.5m
620
528
1620
280
464
399
95
202.5
718
87
97
73