Other Precautions - YASKAWA E-V Series User Manual

Ac servo drives dc power input rotational motor
Hide thumbs Also See for E-V Series:
Table of Contents

Advertisement

2 Installation

2.4.2 Other Precautions

2.4.2

Other Precautions

 Recommended Noise Filter
For more information on recommended noise filters, refer to
alog. (Catalog No.: KAEP S800000 42)
 Fixing the Cable
Fix and ground the cable shield using a piece of conductive metal.
• Example of Cable Clamp
Host controller side
 Shield Box
A shield box, which is a closed metallic enclosure, is effective as reinforced shielding
against electromagnetic interference (EMI) from SERVOPACKs. The structure of the
box should allow the main body, door, and cooling unit to be attached to the ground.
The box opening should be as small as possible.
<Note>
Do not connect the digital operator and the analog monitor cable to the SERVOPACK
during operations. Connect them only when the machinery is stopped during mainte-
nance.
2-12
Cable
Ground plate
clamp
Cable
Shield (cable sheath stripped)
Fix and ground the cable shield
using a piece of conductive metal.
Remove paint on mounting surface.
Σ
-V Series Product Cat-

Advertisement

Table of Contents
loading

This manual is also suitable for:

E-7mini seriesE-vmini seriesSgm7mSgmmvSgdv

Table of Contents