Connection to evaluation devices

Make sure that the selected evaluation device has the following properties:
}
2-channel with feasibility monitoring
}
OSSD signals are evaluated

Single connection

Connection to Pilz evaluation devices

The safety switch PSEN cs6.11n can be connected to Pilz evaluation devices, for example.
Suitable Pilz evaluation devices are, for example:
}
PNOZelog for safety gate monitoring
}
PNOZpower for safety gate monitoring
}
PNOZsigma for safety gate monitoring
Operating Manual PSEN cs6.11n
1004127-EN-03
CAUTION!
Do not connect the signal output to 0 V!
If the signal output Y32 is connected to 0 V, the safety switch may be dam-
aged as a result. Connect the signal output Y32 to a consumer, e.g. to the
input on a control system, or leave the signal output unconnected. Also note
the max. current (see
Actuator
Technical details [
23]).