Mechanical data
Operating distances when the actuator approaches
square marking
Assured operating distance Sao
Assured release distance Sar
Typical operating distance So
Typical release distance Sr
Typical hysteresis
Min. distance between safety switches
Sensor flush installation in accordance with EN
60947-5-2
Connection type
Material
Max. torque setting for fixing screws
Dimensions
Height
Width
Depth
Actuator dimensions
Height
Width
Depth
Weight of safety switch
Weight of actuator
Weight
Where standards are undated, the 2015-11 latest editions shall apply.

Safety characteristic data

Operating
EN ISO
Mode
13849-1:
2015
PL
2-ch. OSSD PL e
All the units used within a safety function must be considered when calculating the safety
characteristic data.
Operating Manual PSEN cs6.11n
1004127-EN-03
NOTICE
You must comply with the safety-related characteristic data in order to
achieve the required safety level for your plant/machine.
EN ISO
EN 62061
13849-1:
SIL CL
2015
Category
Cat. 4
SIL CL 3
8 mm
20 mm
11 mm
14 mm
2 mm
250 mm
Yes, follow installation guidelines
M12, 5-pin male connector
PA+GF, PBT, polycarbonate
1 Nm
26,4 mm
101,6 mm
19 mm
18 mm
90 mm
19 mm
75 g
60 g
135 g
EN 62061
IEC 61511
PFH
[1/h]
SIL
D
9,56E-10
IEC 61511
EN ISO
13849-1:
PFD
2015
T
[year]
M
8,51E-06
20
25