PSEN cs6.11n

Technical details

General
Approvals
Sensor's mode of operation
Coding level in accordance with EN ISO 14119
Design in accordance with EN ISO 14119
Classification in accordance with EN 60947-5-3
Pilz coding type
Transponder
Frequency band
Max. transmitter output
Electrical data
Supply voltage
Voltage
Kind
Voltage tolerance
Output of external power supply (DC)
Max. switching frequency
Max. cable capacitance at the safety outputs
No-load, PNOZ with relay contacts
PNOZmulti, PNOZelog, PSS
Max. inrush current impulse
Current pulse, A1
No-load current
Semiconductor outputs
OSSD safety outputs
Signal outputs
Switching current per output
Breaking capacity per output
Potential isolation from system voltage
Short circuit-proof
Residual current at outputs
Voltage drop at OSSDs
Conditional rated short circuit current
Lowest operating current
Utilisation category in accordance with EN 60947-1
Times
Test pulse duration, safety outputs
Switch-on delay
after UB is applied
Actuator typ.
Actuator max.
Operating Manual PSEN cs6.11n
1004127-EN-03
CE, EAC (Eurasian), ECOLAB, FCC, IC, TÜV, UL/
cUL
Transponder
High
4
PDDB
fully coded
122 kHz - 128 kHz
15 mW
24 V
DC
-20 %/+20 %
1 W
3 Hz
40 nF
40 nF
0,5 A
25 mA
2
1
100 mA
2,4 W
No
yes
400 µA
1 V
100 A
2 mA
DC-12
150 µs
1 s
30 ms
50 ms
23