Normal Mode; Error Display - Pilz PSEN cs6.11n Operating Manual

Table of Contents

Advertisement

PSEN cs6.11n

Normal mode

Device
Safety gate
Input
LED display actuator teach-in
Device
Green
Green

Error display

Device
red
red
yellow
red
green
Operating Manual PSEN cs6.11n
1004127-EN-03
LED status
Ready for operation
green
Actuator is within the response range
yel-
low
Actuator is outside the response range
Off
The unit is ready for operation
yel-
low
LED status
Safety Gate
Input
Display not
definitive
yellow
Display not
definitive
yellow
LED status
Safety Gate
Input
Off
yellow
yellow
Display not
Display not
definitive
definitive
Display of
Display of
last status
last status
Display not
definitive
yellow
Switch status
Switch status
Teaching actuator.
Duration approx. 20
seconds
Actuator teach-in com-
plete.
Switch status
Internal error on
switch
Off
Supply voltage is
outside the toler-
ance range
Supply voltage is at
the limit of the toler-
ance range
Outputs in fault con-
dition
Wrong actuator
Remedy / measure
-
Switch voltage off
and then on again.
Remedy / measure
Change the switch.
Ensure the voltage supply
corresponds to the
Tech-
nical details [
23].
Ensure the voltage supply
corresponds to the
Tech-
nical details [
23].
Check the outputs and
switch the voltage off and
then on again.
Use the actuator PSEN
cs6.11 M12.
20