Pilz PSEN cs1.19n Operating Manual
Hide thumbs Also See for PSEN cs1.19n:

Advertisement

Quick Links

PSEN cs1.19n
}
PSEN sensor technology
Operating Manual-1003269-EN-05

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PSEN cs1.19n and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Pilz PSEN cs1.19n

  • Page 1 PSEN cs1.19n PSEN sensor technology Operating Manual-1003269-EN-05...
  • Page 2 We do assure you that all persons are regarded without discrim- ination and on an equal basis. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    ..................Teaching in the actuator ....................... Installation ..........................Adjustment ..........................Operation ..........................Dimensions in mm ......................... Technical details ........................Safety characteristic data ......................Supplementary data ......................Radio approval.......................... Order reference ........................System ............................Accessories ..........................Operating Manual PSEN cs1.19n 1003269-EN-05...
  • Page 4 Contents EC declaration of conformity ....................UKCA-Declaration of Conformity ..................Operating Manual PSEN cs1.19n 1003269-EN-05...
  • Page 5: Introduction

    PSEN cs1.19n Introduction Validity of documentation This documentation is valid for the product PSEN cs1.19n. It is valid until new documenta- tion is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 6: Safety

    If installed in other environments, measures should be taken to comply with the applicable standards and directives for the respective installation site with regard to in- terference. Operating Manual PSEN cs1.19n 1003269-EN-05...
  • Page 7: Safety Regulations

    Disposal In safety-related applications, please comply with the mission time T in the safety-related characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PSEN cs1.19n 1003269-EN-05...
  • Page 8: For Your Safety

    Transponder technology for presence detection Pilz coding type: Coded Dual-channel operation 2 safety outputs 3 actuators LED display for: – State of the actuator – Supply voltage/fault 4 directions of actuation 5-pin M12 male connector Operating Manual PSEN cs1.19n 1003269-EN-05...
  • Page 9: Function Description

    Actuator in the re- Safety out- Safety output LED OSSD1 LED OSSD2 sponse range put 12 OSSD1 High OSSD2 High OSSD1&2 High High Block diagram A1 A2 Actuator OSSD1 Actuator Receiver OSSD1&2 Power Actuator OSSD2 12 22 Operating Manual PSEN cs1.19n 1003269-EN-05...
  • Page 10: Operating Distances

    Vertical offset 0 10 20 0 10 20 Legend [1] Hysteresis [2] Typical operating distance S [3] Typical release distance S [4] Offset in mm [5] Operating distance in mm [6] Response range Operating Manual PSEN cs1.19n | 10 1003269-EN-05...
  • Page 11: Distance Between Actuators

    The outputs of the safety switch must have a protective separation to voltages over 60 V The supply voltage to the safety switch must be protected with a 2 A to 4 A quick-acting fuse. Ensure the wiring and EMC requirements of EN 60204-1 are met. Operating Manual PSEN cs1.19n | 11 1003269-EN-05...
  • Page 12: Pin Assignment, Connector And Cable

    Black Do not connect Grey The wire colour also applies for the cable available from Pilz as an accessory. Connection to evaluation devices Make sure that the selected evaluation device has the following property: OSSD signals are evaluated through 2 channels with plausibility monitoring...
  • Page 13 PSEN cs1.19n Suitable Pilz evaluation devices are, for example: PNOZelog for safety gate monitoring PNOZpower for safety gate monitoring PNOZsigma for safety gate monitoring PNOZ X for safety gate monitoring PNOZmulti for safety gate monitoring Configure the switch in the PNOZmulti Configurator with switch type 3.
  • Page 14: Teaching In The Actuator

    PSEN cs1.19n Teaching in the actuator Any approved Pilz actuator (see Intended use [ 6]) is detected as soon as it is brought into the response range. Installation CAUTION! The unit's properties may be affected if installed in an environment contain- ing electrically or magnetically conductive material.
  • Page 15: Adjustment

    "OSSD1" and "OSSD2" LEDs light up yellow: Actuators OSSD1&2 are in the response range Fault indicator: "POWER/Fault" LED lights up red: Error message. Remedy: Disconnect power supply and rectify error. Reconnect power supply. Operating Manual PSEN cs1.19n | 15 1003269-EN-05...
  • Page 16: Dimensions In Mm

    PSEN cs1.19n Dimensions in mm Safety switch 21,5 Actuator Operating Manual PSEN cs1.19n | 16 1003269-EN-05...
  • Page 17: Technical Details

    Short circuit-proof Residual current at out- puts 10 µA 10 µA 10 µA Voltage drop at OSSDs 3,5 V 3,5 V 3,5 V Lowest operating current 0 mA 0 mA 0 mA Operating Manual PSEN cs1.19n | 17 1003269-EN-05...
  • Page 18 Acceleration Duration 11 ms 11 ms 11 ms Airgap creepage Overvoltage category Pollution degree Rated insulation voltage 75 V 75 V 75 V Rated impulse withstand voltage 0,8 kV 0,8 kV 0,8 kV Operating Manual PSEN cs1.19n | 18 1003269-EN-05...
  • Page 19 40 mm 40 mm Depth 40 mm 40 mm 40 mm Actuator dimensions Height 11 mm 11 mm 11 mm Width 40 mm 40 mm 40 mm Depth 40 mm 40 mm 40 mm Operating Manual PSEN cs1.19n | 19 1003269-EN-05...
  • Page 20: Safety Characteristic Data

    If this does not occur within a defined time (depending on the ap- plication) the programmable safety system must safely shut down the plant/machine. The behaviour of the feasibility check must be verified during initial commissioning. Operating Manual PSEN cs1.19n | 20 1003269-EN-05...
  • Page 21: Supplementary Data

    2) this product must accept any interference received, including interference that may cause undesired operation. Changes or modifications made to this product not expressly approved by Pilz may void the FCC authorization to operate this equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • Page 22: Order Reference

    PSEN screw M5x20 10pcs Safety screws made from stainless steel with one-way slot 540312 PSEN cs1/2 bracket cable Mechanical protection against defeat, protecting against unau- 532112 thorised cable disconnection or damage for safety switches PSENcode cs1/2, PSENcode cs5/6 M12, PSENslock Operating Manual PSEN cs1.19n | 22 1003269-EN-05...
  • Page 23 20 m 630298 30 m 630297 PSEN cable M12-5af Angled, M12, 5-pin, socket Open cable 630347 630348 10 m 630349 30 m 630350 PDP67 F 8DI ION Decentralised input module IP67 for PNOZmulti 773600 Operating Manual PSEN cs1.19n | 23 1003269-EN-05...
  • Page 24 European Parliament and of the Council. 2006/42/EC on machines 2014/53/EC on radio equipment The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/ downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, Felix-Wankel-Str. 2, 73760 Ost- fildern, Germany...
  • Page 25 We are represented internationally. Please refer to our homepage www.pilz.com for further details or contact our headquarters. Headquarters: Pilz GmbH & Co. KG, Felix-Wankel-Straße 2, 73760 Ostfildern, Germany Telephone: +49 711 3409-0, Telefax: +49 711 3409-133, E-Mail: info@pilz.com, Internet: www.pilz.com...