Connection To Evaluation Devices - Pilz PSEN sl-1.0p 1.1 Operating Manual

Hide thumbs Also See for PSEN sl-1.0p 1.1:
Table of Contents

Advertisement

PSEN sl-1.0p 1.1/1.1 VA

Connection to evaluation devices

Make sure that the selected evaluation device has the following properties:
2-channel with feasibility monitoring
}
OSSD signals are evaluated
}
Connection diagram, single connection
Actuator
Operating Manual PSEN sl-1.0p 1.1/1.1 VA
1003821-EN-12
S11
S31
12
O1 (ST)
I1 (FS)
FS: Failsafe
ST: Standard
24 V
S21
Safety switch
A1
A2
22
I2 (FS)
Evaluation device
A1
A2
0 V
14