Download Print this page

Troubleshooting - 485 - Screen Innovations Nano Box Installation Instructions Manual

24v dc - 485 shades

Advertisement

TROUBLESHOOTING - 485

Problem
Possible Cause
Shade won't
operate.
Please use this QR Code
to access the updated
installation instructions
and related documents.
Troubleshooting - 485
Motor is not powered.
Incorrect or poor cable
termination.
SIFI is not powered.
SIFI is not on the local
network.
Technical Support: 512.832.6939
Hours of Support: 7:30am - 5pm CST
Action to Take
Ensure that 24Volt motors have 24v DC supply and
that the polarity is correct.
Check the wire pinouts and termination. Look for
broken, loose, or damaged wires. Reterminate if
necessary.
Check that the green LED on SIFI is flashing. If not,
make sure power is available via the bus power
supply or PoE (with expansion card only).
Use the service keypad (if available) to validate the
485 network and motors are operating properly
before troubleshooting SIFI network problems.
Check that the SIFI is communicating on the local
network. Ping the device via the windows command
prompt, or make sure the device shows up in the
network tab of the Windows File Explorer.
screeninnovations.com