6.4
Bolt connections tightening torques
Pump on pump flange
Level sensor and maintenance port
Backflow protection device (plastic)
6.5
Effective volumes
Dependence of the effective volume on intake position in approx. litres.
Type
Container capacity
F XL 200
F XL 300
F XL 450
1)
Standard connection, top
Minimum activation level
The minimum height for the intake position <B> is <A>* + 5 cm.
Boring below this level is not allowed in order to prevent the
pump(s) from running dry.
* <A> = distance from container floor to pump blade wheel.
Technical data
Effective volume in approx. litres for intake position [mm]
170 [mm]
200 litres
37
300 litres
50
450 litres
63
7 Nm
5 Nm
7 Nm
[15]
265 [mm]
85
119
156
48 / 60
365 [mm]
Nozzle
112
120
159
175
216
250
A
[16]
1
B
V 1.0