Control unit KESSEL Aqualift F Comfort 400V
Power-up delay [s]
2
Sensor height
Start-up lock [s]
Sensing zone [mm]
ON1 level [mm]
ON2 level [mm]
OFF1 level [mm]
Alarm level [mm]
On delay [s]
Post run time [sec]
- 200l container
- 300l container
- 450l container
6
Pump mode
(Duo only)
7
Max. run time
[min]
8
Max run occur
Min. current [A]
Max. current [A]
9
LEP offset
[mm]
Auto SDS [d]
1)
A = Set, check
2)
Immersion pipe
3)
Time that elapses before the second pump starts (Duo) as well as the time that elapses before a pump can restart.
4)
Only in Duo version
5)
Length of delay to switch-off caused by ventilation of the level detector immersion pipe.
6)
Describes the sequence in which the pumps switch on/off. It is possible to switch between alternating and set
sequence.
7)
Maximum run time of each pump. Observe pump types S1 and S3.
8)
Maximum number of pump start-ups within 3 minutes. Error message (visual and acoustic) if exceeded.
9)
Offset required to adjust the pressure created if a compressor is used to create air bubbles.
V 1.0
5
[mm]
130
3
6
1000
350
4
400
160
450
1
5
3
6
6
On
240
20
1
10
0
7
B = Optional
C = Changes to be carried out only by trained KESSEL personnel.
Assembly
Custom settings for pumps
5
5
130
130
130
6
6
1000
1000
1000
350
350
350
400
400
400
160
160
160
450
450
450
1
1
3
3
6
5
6
6
On
On
240
240
240
20
20
1
1
4
6.3
0
0
7
7
45 / 60
5
5
0...60
130
0...999
6
6
0...30
1000
0...3000
350
0...999
400
0...999
160
0...999
450
0...999
1
1
1...10
2
2
1...10
5
3
1...10
5
4
1...10
On
On
Off/On
240
40...640
20
20
5...30
1
1
0...5
10
14
0...5
0
0
0...30
7
7
0...14
B
A
C
B
A
A
A
A
B
A
A
A
B
B
B
A
A
B
B