7-Segment Led - Mitsubishi Electric MELSERVO-J5 Series User Manual

Ac servo system
Hide thumbs Also See for MELSERVO-J5 Series:
Table of Contents

Advertisement

Test operation select switch (SW3-1)
Turning "ON (up)" the test operation select switch enables the test operation mode. In the test operation mode, functions such
as JOG operation, positioning operation, and machine analyzer are available using MR Configurator2.
Page 47 Test operation
Disabling control axis switches (SW3-2, SW3-3, and SW3-4)
Turning "ON (up)" the disabling control axis switch disables the corresponding servo motor. The servo motor will become in
the disabled-axis state and will not be recognized by the controller.
ID setting switches (SW1/SW2)
A node address for the servo amplifier can be set with the ID setting switches (SW1/SW2). SW1 indicates an upper digit and
SW2 indicates a lower digit of a hexadecimal. The initial setting is 01h.
For how to set node addresses, refer to "Node address setting" in the following manual.
MR-J5-G-N1 User's Manual (Communication Function)

7-segment LED

The network connection status, servo status, and alarm/warning occurrence statuses can be checked on the 7 segment LED
display.
Display sequence
The following shows the display sequence of the 7-segment LED display after power-on. Once a system check is complete
and the servo amplifier is started, the network connection status will be displayed.
Servo amplifier power on
Controller power on
(Network communication start)
*1
Controller power off
*1 The segment of the last 2 digits shows the node address.
Page 33 When the network is connected
3 STRUCTURE
32
3.2 Switch setting and display of the servo amplifier
Controller not connected
Cyclic communication in progress
Controller is connected

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melservo-j5-g-n1Melservo-j5w-g-n1

Table of Contents