Functional safety

Item
Safety sub-function
Safety performance
*1 A test pulse is a signal which instantaneously turns off a signal to the servo amplifier at a constant period for external circuits to perform
self-diagnosis.
*2 The performance of special proof tests within the mission time of the product is regarded as not necessary. For example, on IEC 61800-
5-2:2016, the diagnostic interval is suggested as at least one test per three months for SIL3, Category 3 PL e.

Environment

Item
Operation
Ambient
0 ˚C to 60 ˚C (non-freezing)
temperature
Class 3K3 (IEC 60721-3-3)
Ambient humidity
5 %RH to 95 %RH (non-condensing)
Ambience
Indoors (no direct sunlight); no corrosive gas, inflammable gas, oil mist or dust
Altitude/
Altitude: 2000 m or less
atmospheric
pressure
Vibration resistance
When there is continuous vibration:
10 Hz to 57 Hz, displacement amplitude
0.075 mm
57 Hz to 150 Hz, acceleration amplitude
9.8 m/s
Class 3M1 (IEC 60721-3-3)
When there is continuous vibration:
10 Hz to 55 Hz, acceleration amplitude 5.9
m/s
*1 Refer to "Restrictions when using this product at altitude exceeding 1000 m and up to 2000 m" in the following manual for using the
product at altitude exceeding 1000 m.
MR-J5 User's Manual (Hardware)
1 SPECIFICATIONS
14
1.3 Servo amplifier standard specifications
Specifications
MR-J5-_G-_N1
STO (IEC/EN 61800-5-2)
Satisfied standards
EN ISO 13849-1:2015 Category 3 PL e, IEC
61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2
Response performance
8 ms or less (STO input off → energy shut off)
*1
Test pulse input (STO)
Test pulse interval: 1 Hz to 25 Hz, test pulse off time: Up to 1 ms
Mean time to dangerous
MTTFd ≥ 100 [years] (314a)
failure (MTTFd)
Diagnostic coverage (DC)
DC = Medium, 97.6 [%]
Probability of dangerous
PFH = 6.4 × 10
Failure per Hour (PFH)
*2
Mission time (T
)
T
M
*1
2
2
-9
[1/h]
= 20 [year]
M
Transportation
-25 ˚C to 70 ˚C (non-freezing)
Class 2K3 (IEC 60721-3-2)
5 %RH to 95 %RH (non-condensing)
Transportation conditions: Must be
transported by ground/sea, or air at an
atmospheric pressure of 700 hPa or more.
2 Hz to 8 Hz, displacement amplitude (half
amplitude) 7.5 mm
8 Hz to 200 Hz, acceleration amplitude 20
2
m/s
Class 2M3 (IEC 60721-3-2)
MR-J5-_G-_RJN1/MR-J5W_-_G-N1
EN ISO 13849-1:2015 Category 4 PL e, IEC
61508 SIL 3, EN 62061 SIL CL 3, EN 61800-5-2
DC = Medium, 97.5 [%]
-9
PFH = 1.3 × 10
[1/h]
Storage
-25 ˚C to 70 ˚C (non-freezing)
Class 1K3 (IEC 60721-3-1)
5 %RH to 95 %RH (non-condensing)
Atmospheric pressure: 700 hPa to 1060
hPa
(equivalent to the altitude of -400 m to 3000
m.)
2 Hz to 9 Hz, displacement amplitude (half
amplitude) 1.5 mm
9 Hz to 200 Hz, acceleration amplitude 5
2
m/s
Class 1M2 (IEC 60721-3-1)