1.5

Configuration including peripheral equipment

• To prevent a malfunction, do not connect these connectors to any network other than the specified network.
• Equipment other than the servo amplifier and servo motor is optional or a recommended product.
The following is an example using MR-J5-20G-RJN1.
R S T
Power supply
Molded-case
circuit breaker
(MCCB)
Magnetic
contactor
(MC)
*1
Line noise filter
(FR-BSF01)
L1
L2
L3
Power factor
P3
improving
DC reactor
(FR-HEL)
P4
P+
Regenerative
option
C
*1 The power factor improving AC reactor can also be used. In this case, the power factor improving DC reactor cannot be used.
*2 This is for the MR-J5-_G-RJN1 servo amplifier. The MR-J5-_G-N1 servo amplifier does not have the CN2L connector. If using the MR-
J5-_G-RJN1 servo amplifier in a linear servo system or a fully closed loop system, connect an external encoder to this connector. Refer
to the following for the compatible external encoders.
Page 27 Parts identification
U
V
W
L11
L21
CN1A
CN1B
MR Configurator2
CN5
CN6
Analog monitor
CN8
Safety relay
CN3
Junction terminal block
CN2
*2
CN2L
Servo motor
1 SPECIFICATIONS
1.5 Configuration including peripheral equipment
1
Controller or
servo amplifier
Servo amplifier
Personal
computer
17