Honeywell Intermec PD43 User Manual page 175

Commercial
Table of Contents

Advertisement

PD43 and PD43c Commercial Printer User Manual
Media Settings (Continued)
Setting
Description
Clip Default
Determines if the printer prints items
outside the printable area of the label.
When this is set to Off, the printer returns
an error if any part of a bar code label
cannot be printed because that part extends
beyond the printable area. When this is set
to On, the printer prints all bar code labels,
but may also print unreadable, incomplete
labels.
Start Adjust
Sets the length of media the printer feeds
(positive value) or retracts (negative value)
before printing a label. Unit of
measurement is defined in the Unit of
Measure parameter. Range is -9999 to
+9999.
Stop Adjust
Sets the length of media the printer feeds
(positive value) or retracts (negative value)
after printing a label. Unit of measurement
is defined in the Unit of Measure parameter.
Range is -9999 to +9999.
Media
Selects the mode the printer uses to
Calibration
calibrate media. Use Slow if the printer has
Mode
trouble identifying gaps or marks in media.
Length
If Media Calibration Mode is set to Slow,
(Slow Mode)
the printer prints the media length plus 10
mm. This value sets an additional amount
of media to be printed. Unit of
measurement is defined in the Unit of
Measurement parameter. Range is 0 to
3200.
LTS
Sets the sensitivity of the label taken sensor.
Sensitivity
Range is 0 to 14. Supported when the
Level
Cutter or Label Dispenser accessories are
installed.
Power Up
Sets the action when you turn the printer
Action
on:
No Action
Formfeed - The printer feeds one label.
Testfeed - The printer prints a
configuration label.
Appendix B — Default Settings
Default
Off
0
0
Fast
0
0
No Action
161