Chapter 2 — Set Up the Printer

Run the RFID Calibration Wizard

74
Run the RFID calibration wizard to determine the best Tag Position
and Output Power (UHF inlays, only) for RFID media.
Note: After you determine the correct RFID media settings, you can
save these settings to a printer profile and load the profile when you
need to print on the specific RFID media.
1 Make sure the media type and media length are properly
configured.
2 From the Main Menu, select Wizard > Calibration > RFID
Calibration.
3 To enable the RFID module, select Enable.
4 Load the RFID media.
5 Select OK.
When the calibration is complete, the printer displays the RFID
Tag Position and Output Power (UHF inlays, only).
PD43 and PD43c Commercial Printer User Manual