Operator Start-Up - Manaras Opera MGH Installation Instructions Manual

Commercial & industrial very heavy duty worm gear operator (for sectional doors, rolling doors and grilles), electrical control (board 070e)
Table of Contents

Advertisement

9

Operator Start-up

• Personnel should keep away from a door in motion and keep the moving door in sight until it is
completely closed or opened. NO ONE SHOULD CROSS THE PATH OF A MOVING DOOR.
• Never go under a stopped, partially opened door.
1. Turn power ON.
2. Use on-board, wall-button station (Open/Close/Stop), external entrapment device or jumper wires for testing,
see Table 9.
Table 9 - Start-up and Testing Guide
Test
Door Position
Door at 6" from the
Open
closed position
Door at fully open
Close
position
A) Door at fully
closed position
Sense
Edge
B) Door is closing
(movement)
A) Door at fully
Open &
opened position
Close
B) Door at fully
(single-
closed position
button
radio)
C) Door is closing
(movement)
For technical support, please call 1-800-361-2260 or visit
WARNING
To reduce risk of SEVERE INJURY or DEATH to persons:
Action
1. Press "OPEN".
2. Check if door is stopped
by Open limit switch.
3. If required, re-adjust
Open limit, as shown in
Figure 13, p.13.
1. Press "CLOSE".
2. Check if door is stopped
by Close limit switch.
3. If required, re-adjust
Close limit, as shown in
Figure 13, p.13.
Activate external entrapment
device
OR
Momentarily touch #3 & #5
on the main terminal with a
jumper wire.
Activate the single-button
transmitter
OR
Momentarily touch #3 & #4
on the main terminal with a
jumper wire.
30
Door Response
Door should open instantly.
- C2 mode: (selector switch on
C2=0).
Door should close as long as the
close button is activated.
- B2 mode: (selector switch on
B2=1).
Door should close instantly.
Door should stay at closed
position.
Door should stop and then
reverse to fully opened position.
Door should close.
Door should open.
Door should reverse to fully
opened position.
www.manaras.com
LED Status
"Open Limit"
LED is ON
"Close Limit"
LED is ON
"SENS" LED
is ON as
long as the
contact is
maintained
"O/C" LED is
ON as long
as the
contact is
maintained
(+/- 2 sec)
for more information

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MGH and is the answer not in the manual?

Related Products for Manaras Opera MGH