06.2006
Designation
Order No.
Rated voltage
• Input
• Output
Rated frequency
• Input
• Output
Rated current
• Input
• Output
Motor rated power
Auxiliary power supply
Max. aux. current requirement [A]
• Standard version at 20 V
• Maximum version at 20 V
Pulse frequency fp
Load class II to EN 60 146-1-1
Base load current
Overload cycle time
Overload current *)
Overload duration
Extra short-time loading
Short-time current (fp = 5 kHz) [A]
Short-time current (fp = 10 kHz)[A]
Short-time cycle
Short-time duration
Loses, cooling
Efficiency η (rated operation)
Power loss (fp = 10 kHz)
Cooling air requirement
∆
Pressure drop
p
Sound pressure levels, types of construction, dimensions, weights
Sound pressure level
Dimensions
• Width
• Height
• Depth
Weight approx.
Siemens AG
6SE7087-6KP50
SIMOVERT MASTERDRIVES
6SE70...
21-8TP 0
[V]
[Hz]
[A]
20.8
17.5
[kW]
7.5
[V]
0.8
2.1
[kHz]
Pulse frequencies <5 kHz and >8 kHz are available only with
[A]
[s]
[A]
[s]
[s]
[ms]
[kW]
0.300
[m³/s]
0.041
[Pa]
30
[dB(A)]
48
[mm]
135
360
260
[kg]
9.2
= 5 corresponds to MASTERDRIVES Motion Control
= 7 corresponds to MASTERDRIVES Motion Control Performance 2
*) With a 1.6-fold overload in field weakening, the torque quality is reduced
due to a ripple of 300 Hz.
Table 11-5
Technical data of inverter (part 2)
Operating Instructions
Value
22-6TP 0
23-4TP 0
DC 510 (- 15 %) to 650 (+ 10 %)
3 AC 0 up to rated input voltage x 0.64
---
0 ... 400
30.4
40.5
25.5
34.0
11.0
15.0
DC 24 (20 - 30)
2.5 to 10.0
Performance II units (60SE70_ _-_TP70)
0.91 x rated output current
300
1.6 x rated output current
30
3 x rated output current
2.1 x rated output current
1
250
0.410
0.550
0.041
0.061
30
30
48
59
135
180
360
360
260
260
9.3
13.8
Technical Data
23-8TP 0
44.6
37.5
18.5
0.8
2.4
0.660
0.061
30
59
180
360
260
14.0
11-7
Need help?
Do you have a question about the Simovert Masterdrives Compact Plus Series and is the answer not in the manual?