Siemens Simovert Masterdrives Compact Plus Series Operating Instructions Manual page 289

Motion control frequency inverter (dc-ac)
Table of Contents

Advertisement

Available languages

Available languages

Faults and Alarms
Number / Alarm
Cause
A172
The program number specified in [PROG_NO]
for automatic mode is not stored in the
Program with this
memory of the technology.
number does not exist
Effect:
NC program execution is inhibited.
A173
The program number specified in [PROG_NO]
for automatic mode is not allowed.
Program number not
allowed
Effect:
NC program execution is inhibited.
A174
The program number [PROG_NO] was
changed while the program was running.
Program number
changed during
Effect:
traversing
NC program execution is aborted and the axis
or axes are brought to a standstill via the
deceleration ramp.
A175
The decoded NC block is not terminated with
the following block identifier "0".
No block end
programmed
You can use the "output actual values -
decoder error location" task to read out the
program number and block number where the
block decoder detected an error.
Effect:
NC program execution is inhibited or aborted.
Moving axes are stopped via the deceleration
ramp.
A177
The program number for the main program
(level 0), which was transferred with the block
Prog. number of block
search function, does not exist.
search forwd. does not
exist
Effect:
NC program execution is inhibited.
A178
-The program number for the main program
(level 0), which was transferred with block
Program number of
search, is different from the selected program
block search forward
number.
not allowed
-No breakpoint is known for the "automatic
block search" function (a program abort has
not yet occurred).
-A different program number is stored as the
breakpoint for the "automatic block search"
function.
Effect:
NC program execution is inhibited.
A179
The subprogram number specified with block
search for level 1 or level 2 does not exist.
Prog.No.of block srch
fwd level 1/2 does not
Effect:
exist
NC program execution is inhibited.
A180
The subprogram number transferred with
block search for level 1 is not the same as the
Prog.no. of block
subprogram number in the NC block.
search forward level 1
<> cmd.
Effect:
NC program execution is inhibited.
A181
The subprogram number transferred with
block search for level 2 is not the same as the
Prog.no. of block
subprogram number in the NC block.
search forward level 2
<> cmd.
Effect:
NC program execution is inhibited.
12-26
Counter-measure
-Transfer the program to the technology.
-Select the correct program number.
The permissible range for program numbers is
between 1 and 200.
The program number must not be changed
while the program is running.
Correct the block.
The last block in the sequence must contain
the following block identifier "0".
Specify an existing main program number.
For the block search function, the selected
program number [PROG_NO] must be
specified as the program number for the main
program.
For the block search function, an existing
program number must be specified as the
subprogram number for level 1 or level 2.
For the block search function, the subprogram
number specified in the NC block must be
specified as the subprogram number for level
1.
For the block search function, the subprogram
number specified in the NC block must be
specified as the subprogram number for level
2.
6SE7087-6KP50
Operating Instructions
SIMOVERT MASTERDRIVES
06.2006
Siemens AG

Hide quick links:

Advertisement

Chapters

Table of Contents
loading

Table of Contents