Parameter structure
Keypad and display
Coding
The coding defines the attributes of the parameter as follows.
Coding
{X.XX}
Copied Menu 0 or advanced parameter
RW
Read/write: can be written by the user
RO
Read only: can only be read by the user
Bit
1 bit parameter: 'On' or 'OFF' on the display
Bi
Bipolar parameter
Uni
Unipolar parameter
Txt
Text: the parameter uses text strings instead of numbers.
Filtered: some parameters which can have rapidly changing
FI
values are filtered when displayed on the drive keypad for
easy viewing.
Destination: This parameter selects the destination of an
DE
input or logic function.
Rating dependent: this parameter is likely to have different
values and ranges with drives of different voltage and
current ratings. Parameters with this attribute will not be
transferred to the destination drive by SMARTCARDs when
RA
the rating of the destination drive is different from the
source drive and the file is a parameter file. However, the
value will be transferred if only the current rating is different
and the file is a differences from default type file.
Not copied: not transferred to or from SMARTCARDs
NC
during copying.
PT
Protected: cannot be used as a destination.
User save: parameter saved in drive EEPROM when the
US
user initiates a parameter save.
Power-down save: parameter automatically saved in drive
EEPROM when the under volts (UV) trip occurs. Power-
PS
down save parameters are also saved in the drive when the
user initiates a parameter save.
23.01
Sub block headers
RO
Txt
NC
USEr (0), SEt UP (1),
diAGnoS (2), triPS (3), SP
LOOP (4), Fb SP (5), SintEr
(6) , inPut (7)
Defines the sub block headers. Can be used by the MP-Keypad to
display the same strings as the SM-Keypad.
23.02
OR of pre-defined sub block enables
RO
NC
0 to 127
The OR of Pr 23.03 to Pr 23.09. To be used by the MP-Keypad.
Parameter
Value
23.03
1
23.04
2
23.05
4
23.06
8
23.07
16
23.08
32
23.09
64
6
Parameter description
Parameter x.00
Attribute
PT
BU
USEr (0)
PT
BU
0
www.controltechniques.com
Advanced parameter
format
descriptions
23.03 - 23.09
Pre-defined sub block enable
RW
Bit
0 to1
When this parameter is set to 1 the associated pre-defined sub block is
accessible. When this parameter is 0 the associated pre-defined block is
bypassed.
Parameter
23.03
Set up
23.04
Diagnostic
23.05
Trips
23.06
Speed loop
23.07
Speed feedback
23.08
Serial interface
23.09
IO
1.2

Pre-defined sub blocks

Menu 0
Parameter
0.01 to
0.20
Set-up
Menu 0
Parameter
0.21
1.00
0.22
1.07
0.23
1.06
0.24
2.11
0.25
2.21
0.26
1.14
0.27
5.09
0.28
5.07
0.29
5.08
0.30
11.42
0.31
5.70
0.32
5.73
0.33
5.77
0.34
5.12
0.35
11.44
Diagnostic
Menu 0
Parameter
0.36
1.01
0.37
1.03
0.38
2.01
0.39
3.01
0.40
3.02
0.41
3.04
0.42
4.03
0.43
4.01
0.44
5.56
0.45
5.02
0.46
1.11
0.47
1.12
0.48
1.13
0.49
11.29
0.50
0.00
Serial comms
Performance
protocol
1
Description
Display
SEt UP
diAGnoS
triPS
SP LOOP
Fb SP
SintEr
InPut
Description
Configured by Pr 22.01 to
Pr 22.20
Description
Parameter 0
Minimum reference clamp
Maximum reference clamp
Acceleration rate
Deceleration rate
Reference selector
Armature rated voltage
Motor rated current
Base speed
Parameter cloning
Rated field current
Rated field voltage
Enable field control
Autotune
Security status
Description
Speed reference selected
Pre-ramp reference
Post ramp reference
Final speed reference
Speed feedback
Speed controller output
Torque demand
Current Magnitude
Field current feedback
Armature voltage
Reference enabled indicator
Reverse selected indicator
Jog selected indicator
Software version
Spare
Mentor MP Advanced User Guide
Issue Number: 1
US
BU
Display
Display
SE00
SE01
SE02
SE03
SE04
SE05
SE06
SE07
SE08
SE09
SE10
SE11
SE12
SE13
SE14
Display
di01
di02
di03
di04
di05
di06
di07
di08
di09
di10
di11
di12
di13
di14

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents