Emerson Mentor MP Advanced User's Manual page 137

High performance dc drive 25a to 7400a, 480v to 690v two or four quadrant operation
Hide thumbs Also See for Mentor MP:
Table of Contents

Advertisement

Parameter
Keypad and
structure
display
Pr 11.38 String
Type/mode
0
FrEE
Value when Pr 11.37 = 0
1
3C.SE
Commander SE mode parameter file (not used)
2
3OpEn.LP
Open-loop mode parameter file
3
3CL.VECt
Closed-loop vector mode parameter file
4
3SErVO
Servo mode parameter file
5
3REGEn
Regen mode parameter file
6-8
3Un
Unused
9
4C.SE
Commander SE mode difference from default file (not used)
10
4OpEn.LP
Open-loop mode difference from default file
11
4CL.VECt
Closed-loop vector mode difference from default file
12
4SErVO
Servo mode difference from default file
13
4REGEn
Regen mode difference from default file
14-16
4Un
Unused
17
LAddEr
Onboard Application Lite user program file
A file containing user defined data (normally created by an SM-
18
Option
Applications option module)
A file containing user defined data (normally created by an SM-
19
OptPrg
Applications option module user program (Digitax ST only)
11.39
SMARTCARD data version
Bit
SP
Coding
Range
0 to 9,999
Default
0
Update rate
Background read/write
Gives the version number of the data block. This is intended to be used when data blocks are used as drive macros. If a version number is to be
stored with a data block this parameter should be set to the required version number before the data is transferred. Each time Pr 11.37 is changed by
the user the drive puts the version number of the currently viewed data block in this parameter.
11.40
SMARTCARD data checksum
Bit
SP
Coding
Range
0 to 65,335
Update rate
Background write
Gives the checksum of the data block, space left on the card, the total space on the card for the card flags see Pr 11.37 for details.
11.41
Status mode time-out
Bit
SP
Coding
Range
0 to 250 s
Default
240
Update rate
Background read
Sets the timeout for the drive display to revert to status mode from edit mode following no key presses. Although this parameter can be set to less
than 2s, the minimum timeout is 2s.
11.42
Parameter cloning
Bit
SP
Coding
Range
0 to 4
Default
0
Update rate
Background read
* Modes 1 and 2 are not US (i.e. not saved when drive parameters are saved), mode 3 and 4 are US.
Mentor MP Advanced User Guide
Issue Number: 1
Parameter description
Parameter x.00
format
FI
DE
Txt VM DP
ND
FI
DE
Txt VM DP
ND
1
FI
DE
Txt VM DP
ND
FI
DE
Txt VM DP
ND
1
www.controltechniques.com
Advanced parameter
descriptions
RA NC NV
PT
US RW BU
1
1
RA NC NV
PT
US RW BU
1
1
RA NC NV
PT
US RW BU
1
1
RA NC NV
PT
US RW BU
1
*
1
Serial comms
Performance
protocol
PS
1
PS
1
PS
1
PS
1
Menu 11