(1) Radiator Cap
(2) Reservoir Tank
(A) FULL
(B) LOW
6. Install the radiator cap securely.
7. Start and operate the engine for few
minutes.
8. Stop the engine and let cool.
9. Check coolant level of reservoir tank
and add coolant if necessary.
EX35(C)
8.0 (2.1U.S.gal.)
EX40(C)
8.9 (2.4U.S.gal.)
EX45(C)/50(C)
8.7 (2.3U.S.gal.)
! ! ! ! !
CAUTION
To avoid accidents:
Do not remove the radiator cap
while the coolant is hot. You can
get burnt by hot steam. Make
sure to remove it after the cool-
ant is cooled down enough.
Even though the coolant is
cooled down, turn the cap to its
first stop and then wait until it is
H11O644A
depressurized before removing
the cap completely.
IMPORTANT
Do not start engine without
cool-ant.
Use clean, fresh water and anti-
freeze to fill the radiator and
reservoir tank.
When the anti-freeze is mixed
with water, the anti-freeze mix-
ing ratio must be less than 50%.
Securely tighten radiator cap. If
the cap is loose or improperly
fitted, water may leak out and
the engine could overheat.
MAINTENANCE
IMPORTANT
If the radiator cap has to be
removed, follow the caution
above and securely retighten
the cap.
Use clean fresh water and anti-
freeze to fill the reservoir tank.
If the coolant leaks, contact your
local KIOTI Dealer.