Draft Control; Draft Control; Mixed Control; Mixed Control - Kioti LX500L Owner's Manual

Table of Contents

Advertisement

DRAFT CONTROL

(1) Draft Control Lever
1. The draft control is used to do draft
work with an attachment, like a plow,
attached to the 3-point linkage.
2. In the floating range. The attach-
ment will completely lower.
3. In the draft control range, the hy-
draulic unit will have a force to lift
the attachment. In this stage, it is
possible to do stable work without
slipping.
LX500_en_om_07.indd 3
4. If the draft force is higher than the
resistance of the attachment, the
attachment will be lifted up. If it is
lower than the resistance of the
attachment, the attachment will be
restored to its original state.
5. By placing the lever closer to shal-
low, the attachment can be lifted up
by smaller draft resistance.
t85O520a
HYDRaULIC UNIT

MIXED CONTROL

(1) Ground Surface
(2) Soft Soil
(3) Implement Penetration Limit
In draft control, when draft decreases,
the implement automatically lowers
to increase draft. However, the imple-
ment sometimes lowers too much. To
limit the degree, the implement can be
lowered, set the position control lever
at the lowest working depth desire for
the implement. Lower the draft control
lever to the point where the implement
is at the desired depth.
This stops the implement from going
too deep and causing loss of traction
and ground speed.
7

-
t85O521a
7
2012-11-27 오후 3:09:05