Location Configuration Prevention; Cabinet Configuration; Power Requirements; Installation Tools And Device - Bdcom S2518PB Hardware Installation Manual

Table of Contents

Advertisement

For location planning and device locating, refer to section 2.3.2 "Location Configuration
Prevention".
2.3.2

Location Configuration Prevention

The following preventive measures assist you to design the proper environment for the
switch.
 Make sure that the workshop is well-ventilated, the heat of TX devices is
 Put the chassis at the place where cool air can blow off the heat inside the
2.3.3

Cabinet Configuration

The following content assists you to make a proper cabinet configuration:
 Each device on the cabinet gives off heat when it runs. Therefore, the sealed
 When you install the chassis at the open cabinet, prevent the frame of the
 Ensure that nice ventilation is provided for the devices installed at the bottom of
 The clapboard separates exhaust gas and inflow air, and boost the cool air to
2.3.4

Power Requirements

Make sure that the power supply has nice grounding and the power at the input side of the
switch is reliable. The voltage control can be installed if necessary. At least a 240 V, 10A fuse
or a breaker is provided in the phase line if you prepare the short-circuit prevention measures
for a building.
Caution:
If the power supply system does not have good grounding, or the input power disturbs too
much and excessive pulses exist, the error code rate of communication devices increases and
even the hardware system will be damaged.

2.4 Installation Tools and Device

The tools and devices to install the S2518PB switch are not provided by the S2518PB
switch. You yourself need to prepare them. The following are the tools and devices needed for
the typical installation of the S2518PB switch:
 Screwdriver
 Static armguard
 Bolt
 Ethernet cable
 Other Ethernet terminal devices
 Control terminal
well-discharged and sufficient air circulation is provided for device cooling.
chassis. Make sure the chassis is sealed because the opened chassis will
reverse the cool air flow.
cabinet must have the heat-discharge outlet and the cooling fan. Do not put the
devices too close, avoiding bad ventilation.
cabinet from blocking the airway of the chassis.
the cabinet.
flow in the chassis. The best location of the clapboard is decided by the air flow
mode in the chassis, which can be obtained through different location tests.
S2518PB Hardware Installation Manual
- 7 -