Error Messages - Dataman 48UXP User Manual

Intelligent universal programmer
Table of Contents

Advertisement

Error Messages

Cold not open file – nnnn!
This file does not exist. You might have typed the wrong filename
or you might be logged to a different directory.
Verify the filename and the directory, and change to the correct
directory before typing in the filename.
Data file version unmatched!
This message will be displayed one of the data-files of the
Dataman-48UXP software is of the wrong version.
This error occurs if Dataman-48UXP.exe is updated, and the data
files not updated. This might happen if the installation procedure
did not complete.
Re-install the latest release of the Dataman-48UXP software.
Device Code unmatched!
This error message is returned when the Dataman-48UXP does a
device ID check.
The device code found on the device is not as expected. You might
have selected an incorrect device as active device, or the device is
an older/newer version than the device supported by the
Dataman-48UXP. Disable the ID check in device operation option
can be a temporary solution to program the chip if the chip ID is
missing. Select the correct device as active device.
If the error still occurs, download the latest release of software from
our web. If you are sure that the device you are using uses the same
programming algorithm as a device that is supported, you can use
this device as active device. You can then disable device code
checking by setting the Operating Options.

Advertisement

Table of Contents
loading