Qpm-243 Control P.c.b - Horizon Fitness PF-P3100 Manual

Hide thumbs Also See for PF-P3100:
Table of Contents

Advertisement

6 Electrical Circuit

6 - 3 QPM-243 Control P.C.B.

1
LED and DSW on QPM-243
6 - 3 -
Insert the fuse 250VAC,3.5A.
QPM-243
F2
inch: Set DSW 3 to ON.
inch: Set DSW 3 to ON.
mm: Set all switches to OFF.
mm: Set all switches to OFF.
!
Disconnect the
power cable
before replacing
1
2
the fuse.
DSW 1
DSW 1
Control Board
Bottom View
1 2 3 4
6 - 3 - 1 LED and DSW on QPM-243
LED
L14
Download mode is operated. (NMI interruption)
L15
5 VDC is generated on P.C.B.
L16
24 VDC is generated on P.C.B.
L17
Operation check of the debug LED P.C.B. (Blinking at intervals of 1 second)
L19
S13 Feed Table Sheet Detection Switch is ON.
L20
Feed table is up, and S12 Feed Bar Switch is OFF.
L21
B21 1st Buckle Chute Proximity Sensor 1 is ON.
L22
B22 2nd Buckle Chute Proximity Sensor 2 is ON.
L23
Normally lit. The light turns off when the motor (M10) driver outputs alarm.
L24
Normally lit. The light turns off when F2 fuse for 24 VDC is blown.
L26
The buckle chute is inserted to the X20 buckle chute connector.
L27
S10 Fold Section Cover Switch is OFF. (Open)
L28
Normally lit. The light turns off when the interlock is activated.
3
4
Board Name
SW5
SW4
EPROM
SW6
Lighting Condition
SW3
SW2
SW1
6-6
503013
6_3_1A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents