A sample plot is shown in Figure C-3.
Figure C-3:
If you do not have access to a Hewlett Packard 4194A Impedance/Gain-Phase
Analyzer, you can get a close reading by using a function generator, a 50-ohm
terminator and an oscilloscope as shown in Figure C-4.
Function
Generator
Setup for Measuring Tow Cable Characteristics using a
Figure C-4:
Function Generator, Terminator and Oscilloscope
With the function generator and the oscilloscope connected to the cable, monitor
input on the oscilloscope and input a 1 volt peak (2 volt peak-to-peak) sine wave of
Tow Cable Considerations
Sample Plot of Tow Cable Characteristics
50 ohm terminator
Cable
Assembly
C-29
Scope