Operating Parameters

Example 1

To turn the heaters on at 0600 and turn them off at 0015 every day of the
week:
Par 55 = 0600
Par 56 = 0015
Par 60 = - - - -
Par 61 = - - - -
Par 71 through 77 = 1

Example 2

To turn the heaters on at 0700 and off at 1700 Monday through Friday, and
turn the heaters off Saturday and Sunday:
Par 55 = 0700
Par 56 = 1700
Par 57 = - - - -
Par 58 = - - - -
Par 71 through 75 = 1
Par 76 and 77 = 0

Example 3

To turn the heaters on at 0600 each morning, go into standby for lunch at
1130, come out of standby after lunch at 1230, and turn the heaters off at
1600 at the end of the day, every day of the week:
Par 55 = 0600
Par 56 = 1600
Par 57 = 1130
Par 58 = 1230
Par 71 through 75 = 1
Par 71 and 77 = 1