Nordson AltaBlueA4TP Customer Product Manual page 165

Tt adhesive melter
Table of Contents

Advertisement

Is the Heaters key LED
illuminated?
+
Does the right display
indicate that components
are still heating up?
+
? W ait for all components to
reach setpoint
temperature.
Is a remote input being
used to control the
heaters?
+
Wait the the input to initiate
the heaters or use the
Heaters key to manually
turn the heaters on.
Is the ready delay counting
down?
+
Wait for the ready delay to
count down.
Refer to Appendix B,
parameter 4.
Is the clock LED on?
+
The current clock schedule
has the heaters turned off.
Is the standby LED on?
+
The melter is in the
standby mode.
Refer to Standby Key in
Section 4, Operation.
Press the Heaters key to
turn the heaters on.
T.3
No faults >
Ready LED is not illuminated
Replace the tank or the
pump heater.
Refer to Section 7, Parts.
Is the resistance correct for
?
the tank heaters (2) and
the pump heater (1)? Refer
to Heater Specifications in
Section 8 for resistance
values.
+
Contact Nordson for
technical assistance.