Item Number
Indicators
DS2
Neon
DS3
Neon
DS4
Neon
DS5
Neon
DS6
Neon
DS7
Neon
DS8
LED
DS9
LED
DS10
LED
DS11
LED
DS12
LED
DS13
LED
DS14
LED
DS15
LED
DS17
LED
Fuses
F1/F2
−−
F3/F4
−−
F5/F6
−−
F7/F8
−−
F9/F10
−−
F11/F12
−−
Part 1107600_03
Tables 6‐15 through 6‐17 provide detailed descriptions of the circuit board
indicators, connection points, and test points that are referred to in the
troubleshooting chart. Figure 6‐1 illustrates the location of each of these
circuit board components.
Table 6-15 Main Board Components
Type
Power to tank heater
Power to pump heater
Power to 5 VDC and 24 VDC power supplies
Power to hose/gun 1 heaters
Power to hose/gun 2 heaters
Power to motor
Control signal for hose 1 heater
Control signal for gun 1 heater
Control signal for tank heaters
Control signal for motor
Control signal for gun 2 heater
Control signal for hose 2 heater
Control signal for pump heater
+5 VDC control voltage present
Trigger closure present at XP3 or XP4
Tank heaters (10 A, 250 V, fast-acting)
5 VDC and 24 VDC power supplies (2A, 250 V, slow-blow)
Pump heater (5 A, 250 V, fast-acting, 5 x 20 mm)
Hose/gun 1 heaters (6.3 A, 250 V, 5 x 20 mm)
Hose/gun 2 heaters (6.3 A, 250 V, 5 x 20 mm)
Motor start (6.3 A, 250 V, 5 x 20 mm)